AUTOMATIC IDENTIFICATION
If case of a battery with an ID010, the Touch goes into an automatic identification mode
AUTOMATIC IDENTIFICATION
Select the number of batteries
connected to the park
and validate
2
Exit
!!! Warning, the identification is done battery by battery. The first battery is connected, the
identification done, then the second, then the third, etc.... A 120 Ohms resistor is plugged on
the communication port of the battery during the identification.
AUTOMATIC IDENTIFICATION
Connect the second battery
and validate
Exit
If a problem occurs during the identification (or if several batteries have the same ID), press Exit
and then Start Scan during 10 to 15 seconds. A new automatic identification can start again.
AUTOMATIC IDENTIFICATION
Connect only one battery
and validate
Exit