Descargar Imprimir esta página

Xtrails ADPRO PRO E-400H Guía De Instalación Rápida página 2

Publicidad

Opening of housing bracket
Housing cover
TM
360PROtect
Masking Detection lenses
Filter (window)
Bracket cover
Removal from mounting surface tamper
contact adjustment screw
(refer to Fig. "Bracket Tamper Adjustment)
Opening of housing
Bead
Notch
Locking screws
Compliant seal
Application of iCommission on swivel bracket
Telescopic sight mounting
block (comes with alignment
telescope)
iCommission
Side covers
w/ breakout cuts
for hose clamps
Bracket Tamper Adjustment
Pin assignment and output event selection
Pin
Label
Description
lens
1
GND Supply
Ground or AC
2
V+ Supply
V+ or AC
3
RS485 B
High level interface
bus RS485
4
RS485 A
5
OUT 5
Freely programmable
output 5
6
7
OUT 4
Freely programmable
output 4
8
9
OUT 1 (Alarm)
Freely programmable
output 1
10
11
1 End (AE)
End of Line for output 1
12
OUT 3 (Fault)
Freely programmable
output 3
13
14
OUT 2
Freely programmable
(Tamper)
output 2
15
16
2 End (TE)
End of Line for output 2
References
Name and Document Number
Installation manual
ADPRO PRO E-PIR Installation Manual, Doc. No. 27386
(English) and 26570 (German)
Setup Manual
ADPRO PRO E PIR System Setup Manual, Doc. No. 26571
(English) and 27332 (German)
Design and Planning Manual
ADPRO PRO E Design and Planning Manual, Doc. No 27387
(English) and 26570 (German)
Technology Manual
ADPRO PRO E PIR Introduction to PIR Technology, Doc. No
27385 (English) and 26568 (German)
Firmware & Firmware update tool
Setup Flashloader 2.0 (32 and 64 bit) or above
Firmware version 1.41 or above for PRO E-detectors
Recommended fixing
d
8 mm
0
h
50 mm
1
L
40 mm
D
d
4.5 - 5 mm
S
d
47.5 mm
bracket guide
L
90 mm
S
F
2 Nm
Note: shipped detector is already pre-set to correct model.
Do not change.
Function
Power supply
10.5 - 30 VDC, 24 VAC ±15% auto-sensing
Data interface for commissioning and real
time alarm management
Default: Creep zone alarm
Default: Anti-masking alarm
Default: Alarms from main zone(s)
End of line cabling. Refer to pin assignment
Default: Fault: (low power, heating error, flash
problems, wrong rotary switch setting, power
on sequence)
Default: Cover open/Alignment change/
Bracket open/Anti-masking
End of line cabling. Refer to pin assignment
L
S
F
d
d
0
s
d
L
bracket guide
D
h
1
Terminal block and pin assignments
End of Line
End of Line
Cabling
Cabling
R
R
Drilling template
Tools
• Screw driver ≥140 mm
• Alignment Telescope
• iCommission
• PRO E-IFM-ST USB
A
B
Interface Module
• PRO E-IPM IP Module

Publicidad

loading