FILTER REPLACEMENT

EAP150
There are two separate filters: Carbon Pre-Filter and HEPA
13 filter.
The Check Filter indicator will signal when to replace
the HEPA 13 filter. The replacement period will vary
depending on the hours of usage, air quality, and
location of the unit. However, in most cases of normal
use, the filter will need to be replaced annually.
For best performance, change the Carbon Pre-Filter
every three months.
The filters should be disposed off when changed. Do not
wash and reuse the HEPA 13 filter or the Carbon Pre-Filter as
they will not work effectively.
CAUTION: Turn off the air cleaner and unplug the
electrical cord before performing any maintenance.
Carbon Pre-Filter replacement.
1. Turn off the air cleaner and unplug the electrical cord.
2. Remove the front panel by pulling gently from the lower
portion of the panel. Do not force, the panel should
remove easily.
3. Remove the Carbon Pre-Filter by gently pulling out from
the bottom and down from the top.
4. Remove the Carbon Pre-Filter and dispose of it.
5. Remove a replacement Carbon Pre-Filter from the
resalable plastic bag and reseal to maintain the
freshness of the remaining filter.
6. Install the Carbon Pre-Filter.
EAP300
There are two separate filters: Carbon Pre-Filter and HEPA
13 filter.
The Check Filter indicator will signal when to replace
the HEPA 13 filter. The replacement period will vary
depending on the hours of usage, air quality, and
location of the unit. However, in most cases of normal
use, the filter will need to be replaced annually.
For best performance, change the Carbon Pre-Filter
every three months.
The filters should be disposed off when changed. Do not
wash and reuse the HEPA 13 filter or the Carbon Pre-Filter as
they will not work effectively.
CAUTION: Turn off the air cleaner and unplug the
electrical cord before performing any maintenance.
.
Carbon Pre-Filter replacement.
1. Turn off the air cleaner and unplug the electrical cord.
2. Remove the front panel by pulling gently from the lower
portion of the panel. Do not force, the panel should
remove easily.
3. Remove the Carbon Pre-Filter and plastic frame by
gently pulling out from the bottom and down from the
top.
4. Remove the Carbon Pre-Filter from the plastic frame and
dispose of it.
5. Remove a replacement Carbon Pre-Filter from the
resalable plastic bag and reseal to maintain the
freshness of the remaining filter.
6. Install the Carbon Pre-Filter onto the plastic frame by
pushing against six "hook and loop" squares on the back
of the frame.
EAP450
CAUTION: Turn off the air cleaner and unplug the
electrical cord before performing any maintenance.
Filter
Service
Cleaning
life
Cycle
Washable
12 month
Every 3
Pre filter
month
Washable
12 month
Every 3
HEPA 13
month
filter
Carbon
12 month
-
filter
Filter
12 month
-
Cassette
The Check Filter indicator will signal when to replace the
entire Filter Cassette. The replacement period will vary
depending on the hours of usage, air quality, and location
of the unit. However, in most cases of normal use the filter
will need to be replaced annually.
This Filter Cassette should be disposed of when changed.
Filter Cassette replacement
1. Turn off the air cleaner and unplug the electrical cord.
2. Remove the front panel by pulling gently from the lower
portion of the panel. Do not force, the panel should
remove easily.
3. Remove the Filter Cassette by gently pulling out from
the bottom and down from the top.
4. Remove all the filters from the plastic frame and dispose
of it.
5. Remove the replacement filters from the plastic bag and
replace them.
6. Plug in air cleaner and press POWER button until short
"beep" sounds.
7. Press the RESET FILTER button by gently inserting a
paperclip into the RESET FILTER hole on the control
panel. The light will flash 5 times before a "beep" sounds
to indicate the filter has been reset.
BG
CS
DA
DE
EE
EN
ES
FI
FR
How to clean
HR
Clean with vacuum
HU
cleaner or soft brush,
Use warm water when
the filter is very dirty
IT
Put the filter into warm
water for 30 minutes and
LT
dry it out in the shade
for 24 hours
LV
Never wash and reuse
the Carbon filter as it will
NL
not work effectively.
-
NO
PL
PT
RO
RU
SK
SL
SR
SV
TR
UK
41

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Oxygen eap300Oxygen eap450

Tabla de contenido