6
Troubleshooting
6
Troubleshooting
Problem
Expected number of test
rundowns is not
achieved with one
charge of the battery.
No LCD display
Changing LCD display
Charger indicates bat-
tery fault
7
Service
Keep contacts free from contaminations. This is the only way to ensure smooth functioning.
8
Maintenance
NOTE
If repair is required, send the complete battery to our Sales & Service Center!
It may be repaired only by authorized technicians. Opening the battery will void the warranty.
9
Technical data
Features
Battery type
Nominal capacity
Rated voltage
Maximum voltage
Battery self-discharge
Default settings
Fully charged
Weight
26
All manuals and user guides at all-guides.com
EN
Possible cause
Battery is not fully charged.
The warning threshold for undervol-
tage is not set to minimum value.
A high torque was required for the
rundowns, e.g. for coated screws or
for several revolutions.
Battery has too many charging
cycles.
Battery is in Deep Sleep Mode
Battery is defective
Battery temperature is > 118.4° C
Battery detecting short-circuit
Battery is defective
1
:
P2070BA/EN 2011-06
Measure
Use fully charged battery.
Set the undervoltage to 37,2 Volt
using the control on the tool
screen.
Using a high torque for a longer
period of time will reduce the number
of rundowns to be achieved with one
battery charge.
After 800 charging cycles the capac-
ity is reduced to approx. 60%.
Recharge battery with charger
Replace battery
Leave the battery to cool. Display
expires.
Remove short-circuit.
Push battery on to battery
charger. This will reset the error
message.
Replace battery
Data
Lithium ions (Li-Ion), 12 cells
1650 mAh / 72.6 Wh
44.4 V
50.4 V
100 days
360 days
850 g
70b_1_5 en.fm, 12.03.2015