EN
3.3 Programming on initial
installation of the module
The Arrow
module is supplied with a se-
EVO
ries of set-up data already set to the default
values.
On first installation, after activating the
module, you can change the settings if nec-
essary using:
– Evo Console PC (MS Windows) – download
from www.maddalena.it in the software
section
3.4 Troubleshooting
FAULT
The radio module is not
transmitting
The LED of the radio
module does not light up
during installation
WARNING!
l
For a complete list of alarms, please refer to the specific manual.
– Evo app (Android OS) – download from
These two programs can be used to change
the radio's default settings.
CAUSE
Electrical or electronic
devices interfere with the
signal
Battery empty
Mechanical fraud alarm
active
Fixing screw stripped
Faulty module
Mechanical fraud alarm
active
Google Play Store
SOLUTION
Move devices to a sufficient distance
away
Move the receiver closer
Replace the battery (contact the metering
operator)
Contact the metering operator
Contact the metering operator
Contact the metering operator
Contact the metering operator