Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Motion Sensing
Porch Light
PF-4305
FEATURES
• Light comes on when motion is detected.
• Automatically turns light off.
• Photocell keeps the light off during daylight
hours.
This package includes:
• Porch Light
• Easy to use Universal Mounting Bracket
• Mounting Hardware
• Wire Nuts
• Lens Shield
REQUIREMENTS
• The Light Control requires 120 volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
• Some electrical codes require installation by
a qualified electrician.
Before installation,record the model number
listed inside the fixture.Attach receipt in case
of possible warranty issues.
Model Number:
© 2006 DESA Specialty Products™
OPERATION
Mode:
On-Time
Test
5 Sec
Auto
1, 5, or 10 min
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
for the circuitry to calibrate.
TEST
Set the ON-TIME switch
on the sensor to TEST.
AUTO
Set ON-TIME switch to
1, 5, or 10 minutes.
MANUAL MODE
Manual mode only works at
night because daylight returns
the sensor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1, 5,
or 10 position.
MODE SWITCHING SUMMARY
TEST
ON-TIME Switch at 1, 5, or
10 minutes
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Works: Day Night
x
x
x
x
/
minutes
1
2
ON-TIME
TEST 1 5 10 MIN
ON-TIME
TEST 1 5 10 MIN
1 Second OFF
then...
... back on.
Flip light switch off
for one second then
back on*
598-1168-03

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Portfolio PF-4305

  • Página 1 TEST ON-TIME Set the ON-TIME switch on the sensor to TEST. TEST 1 5 10 MIN AUTO PF-4305 ON-TIME Set ON-TIME switch to 1, 5, or 10 minutes. FEATURES • Light comes on when motion is detected. TEST 1 5 10 MIN •...
  • Página 2 DISASSEMBLE LIGHT FIXTURE INSTALL UNIVERSAL MOUNTING 1. Remove two decorative nuts from light fixture BRACKET cover. For best performance, mount the fixture at least 8 2. Remove cover from base. feet (2.4 m) above the ground. WARNING: Turn power off at circuit Light Fixture Base breaker.
  • Página 3 Other Wiring Options Bare Ground Wire This fixture can be wired to control another standard Ground Screw Metal Junction or motion sensing light fixture(s). See the following Pigtail (not wiring diagrams for proper connections. supplied) Note: All wiring should be run in accordance with White to White the National Electrical Code through conduit or Fixture Bare...
  • Página 4 TESTING White to White Black to Black to Red Black and Black 1. Turn on the circuit breaker and light switch. Red to Black Note: Sensor has a 1 minute warm up period before it will detect motion. When first turned on Ground to wait 1 minutes.
  • Página 5 The sensor is less sensitive to motion directly 1. Break off the amount of lens shield needed to towards it and more sensitive to motion across block the desired area of coverage. coverage area. 2. Cut desired amount of foam tape needed to adhere the lens shield to the sensor lens.
  • Página 6: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not Light stays on 1. Light switch is turned off. 1. There is a heat source like an come on. continuously. 2. Bulbs are loose or burned out. air vent, dryer vent, or brightly- painted, heat-reflective surface in 3.
  • Página 7: Lámpara De Portal Con Detector De Movimiento

    (ON-TIME) en la posición de 1, 5 ó 10 TEST 1 5 10 MIN minutos. MODO MANUAL PF-4305 El modo manual funciona sólo CARACTERÍSTICAS por la noche porque la luz del • La luz se prende cuando se detecta movimiento.
  • Página 8: Desarme El Aparato De Luz

    DESARME EL APARATO DE LUZ INSTALE EL SOPORTE UNIVERSAL 1. Retire las dos tuercas decorativas de la tapa DE MONTAJE del aparato de luz. Para un mejor desempeño, monte el aparato al 2. Retire la tapa de la base. menos a 2,4m del suelo. ADVERTENCIA: Desconecte la energía en Base del aparato el disyuntor.
  • Página 9 Conductor desnudo de conexión a tierra Cuando controle aparato(s) de luz adicionales, debe observarse la potencia máxima del detector Tornillo de conexión a tierra Conductor flexible de movimiento de este aparato.Vea en la ilustración (no provisto) de abajo un ejemplo para el cálculo de la potencia Caja metálica máxima de la lámpara.
  • Página 10: Instale La Base Del Aparato Ala Caja De Empalme

    PRUEBA Es también posible cablear dos luces detectoras de movimientodemodoquecualquieradeellasencienda 1. Prenda el cortacircuitos y el interruptor de ambas luces al mismo tiempo (sistema de control luz. doble).Serecomiendaquesólopersonasconamplios Nota: El detector tiene un período de cerca conocimientos de electricidad conecten este tipo de de 1 minutos de calentamiento antes de configuración.
  • Página 11: Regulación Del Área De Cobertura

    El detector es menos sensible a movimientos 2. Corte la canti- Cubierta de la placa traslúcida hacia el detector y más sensible a movimientos dad necesaria transversales en el área de cobertura. de cinta es- IT Y pumosa que IT IV necesita para M IN Movimiento...
  • Página 12: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se La luz se queda 1. El interruptor de luz está apagado. 1. Hayunafuentedecalorcomovento- enciende. prendida conti- 2. Las bombillas están flojas o que- sasdeaire,respiraderodesecadora, nua-mente. o hay en el área de cobertura una madas.

Tabla de contenido