1. INTRODUCTORY INFORMATION
ENG
The USER MANUAL is an integrant part of Horus chimney and a safety
direction.
All drawings and any other document are property of the manufacturer that
reserves all rights and points that they cannot be made available to third
parties without his written approval. It is therefore absolutely forbidden any
reproduction, even partial, of text and pictures.
Horus flue-less ethanol chimney is intended for decorative and domestic
use
Horus chimneys are produced in compliance with the following standards
on quality and safety concerning fireplaces using ethanol:
•
draft standard UNI E0206C540
•
directive 2001/95/CE of 3th December 2001 on the safety of liquid
fuelled appliances.
•
DIN 4734-1
This manual covers the following models of fireplaces Horus:
Weight
Model
Firebox
Tetris
Farenheit
Libera
Opera
Twist
Excalibur
Rubik
Streep
Lcd
Flower
Steeltree
View
Closer
Bend
Freedom
Zen
Ministreep
Monoside 60
Monoside 90
Monoside 130
Monoside 45 x 90
Biside 60
7
Tank capacity for 1st
in kg
and subsequent fillings
room volume
2 lt – 1,75 lt
27,0
55,0
2 lt – 1,75 lt
2 lt – 1,75 lt
35,0
13,6
2 lt – 1,75 lt
2 x 1 lt – 2 x 0,85 lt
31,5
11,6
2 lt – 1,75 lt
2 lt – 1,75 lt
13,0
40,7
2 lt – 1,75 lt
32,5
1 lt – 0,85 lt
2 lt – 1,75 lt
25,3
41,3
2 lt – 1,75 lt
2 lt – 1,75 lt
22,5
22,5
1 lt – 0,85 lt
1 lt – 0,85 lt
17,5
19,0
1 lt – 0,85 lt
3 lt – 2,75 lt
46,3
28,0
2 lt – 1,75 lt
18,6
1 lt – 0,85 lt
3 lt – 2,75 lt
21,4
23,6
3 lt – 2,75 lt
2 x 2 lt – 2 x 1,75 lt
48,0
25,5
2 lt – 1,75 lt
3 lt – 2,75 lt
21,4
Biside 90
Biside 130
Biside 45x90
Link
Fuoco 1.0
Fuoco 2.0
Fuoco 2.0 Quadro
Fuoco 3.0
2. SAFETY DIRECTIONS
2.1 Do not place flammable materials within 1 metre around the fireplace.
Safety distance is 2 metres.
2.2 Make sure that the wall, table or floor that will house the appliance can
support its weight.
Minimum
2.3 Install the appliance in a place protected from draughts.
48 m
3
2.4 The holes on the chimney, intended for the heat outflow, should never
be obstructed by objects.
48 m
3
48 m
3
2.5 Do not place any flammable element on the appliance.
48 m
3
2.6 Do not tamper with or intentionally damage the safety devices, remove
70 m
3
or hide the warning labels, or modify the characteristics of the chimney.
48 m
3
2.7 Keep away from the chimney children or people who have no
48 m
3
knowledge of the dangers.
48 m
3
2.8 For the functioning of the chimney it is absolutely forbidden to use
40 m
3
fuels different from ethanol distilled at 96%.
48 m
3
2.9 At the end of the life of the chimney, do not disperse it in the
48 m
environment, but contact agencies specialized for disposal.
3
48 m
3
40 m
3
40 m
3
40 m
3
48 m
3
48 m
3
40 m
3
48 m
3
48 m
3
70 m
3
48 m
3
48 m
3
2.10 Do not fill the burner when it is still in use or when it is still hot.
3 lt – 2,75 lt
46,3
28,0
2 lt – 1,75 lt
1 lt – 0,85 lt
18,6
21,4
3 lt – 2,75 lt
3 lt – 2,75 lt
23,6
48,0
2 x 2 lt – 2 x 1,75 lt
2 lt – 1,75 lt
25,5
21,4
3 lt – 2,75 lt
48 m
3
48 m
3
40 m
3
48 m
3
48 m
3
70 m
3
48 m
3
48 m
3
8