Descargar Imprimir esta página

Publicidad

Enlaces rápidos

SK-2520 U3.1
EN
ES
DE
Setup guide - Guía de configuración - Setup-Anleitung - Guide d'installation
安裝手冊 - 安装手册 - 설치 안내서 - セッ トアップガイド
To download the latest version of this document, please visit our website at
https://www.akitio.com/support/user-manuals
Version 1.2
7/10/2018
E15-573X1AA0xx
© 2018 by AKiTiO - All Rights Reserved
AKiTiO assumes no responsibility for any errors or differences between the product you may have and the one mentioned in this document
and reserves the right to make changes in the specifications and/or design of this product without prior notice. The diagrams contained in
this document are for reference and may not fully represent the real product. AKiTiO assumes no responsibility for any loss of data or files.
www.akitio.com
California, USA
FR
CH
KO
J
P
Rear View - Vista posterior - Rückansicht - Vue arrière
背面 - 背面 - 배면도 - リアビュー
USB 3.1 Gen 2 (10 Gbps)
USB Type-C 連接埠
USB Type-C port
USB Type-C 连接端口
Puerto de USB Type-C
USB Type-C 포트
USB Type-C Anschluss
USB Type-C ポート
Port USB Type-C
DC 12V (+12V/3A)
Power receptacle
Toma de alimentación
Netzanschluss
Prise de courant
電源插座
电源插座
전원 콘센트
電源コンセン ト

Publicidad

loading

Resumen de contenidos para Akitio SK-2520 U3.1

  • Página 1 The diagrams contained in this document are for reference and may not fully represent the real product. AKiTiO assumes no responsibility for any loss of data or files.
  • Página 2 LED Indicator - Indicador LED - LED-Anzeige - Voyant DEL 燈號說明 - 灯号说明 - LED 표시등 - LED 灯 Power & Link Status Disk Activity (Left/Right) 橙色 = 電源開啟 紅色 = 錯誤或未裝磁碟 Orange = Power ON Red = Error or empty drive bay 藍色...
  • Página 3 Step 1 Step 2 Flat head screw for 2.5” drives Thread size: M3, Length: 4mm PN: E16-1438320006...
  • Página 4 Step 3 Non-RAID Non-RAID (JBOD) for separate volumes. (1 or 2 disks) RAID 1 Disk mirroring for redundancy. (2 disks) RAID 0 Disk striping for fast transfer rates. (2 disks) SPAN Disk spanning for large storage volumes. (2 disks) RAID Mode - Initial Setup Set the jumper to your preferred RAID mode.
  • Página 5 Step 4 Flat head screw for case Thread size: M3, Length: 6mm PN: E16-1438320000 Flat head screw for case Thread size: M3, Length: 5mm PN: E16-1198005720...
  • Página 6 Step 5 USB Bus Power USB Power Delivery (PD) This device can be used without a power adapter but when two drives are installed, the This device supports USB power delivery (PD), providing 15W of power to laptops that support power consumption per drive cannot exceed 7W.
  • Página 7: Usb Cable

    Step 6 How to format the drive(s) https://www.akitio.com/information-center/ formatting-external-hard-drives USB Cable Always use the USB cable that came included with your product to achieve the best data transfer rates and to support USB power delivery. Utilice siempre el cable USB incluido con el producto para lograr las máximas tasas de transferencia de datos y para admitir la entrega de alimentación USB.
  • Página 8 Replacing a faulty drive Austausch einer defekten Festplatte When a drive fails, the corresponding LED lights up red. If only one drive is defective Wenn eine Festplatte ausfällt, leuchtet die entsprechende LED rot. Wenn nur eine and the RAID mode is set to RAID 1, the data can still be accessed but it’s Platte defekt ist und der RAID-Modus RAID 1 ist, können die Daten nach wie vor recommended to replace the faulty drive immediately.
  • Página 9 更換故障的磁碟 고장난 드라이브 교체하기 當一個磁碟發生故障時 , 相對應的 LED會亮起紅燈 。 如果只有一個磁碟發生故障 , 磁碟陣列模式 드라이브가 제대로 인식되지 않았을 때 LED 등 빨간 불이 들어옵니다. RAID 1 모드일 때 , 하나의 設定為RAID 1的 , 該資料仍然可以讀寫 , 但建議請立即更換有故障的磁碟 。 如果有多個磁碟同時 드라이브에서만 문제가 발생 하였다고 해도 사용가능 하지만, 문제의 드라이브를 빨리 교체하시길 出現故障或者磁碟陣列模式設定為RAID 0或SPAN者...