TROUBLESHOOTING
The door remains
closed.
The LED is OFF.
The door does not
react as expected.
The door closes and
opens constantly.
The door opens for
no apparent reason.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.it - www.came.it
Came S.p.A. hereby declares that MR8107 is in conformity with the basic requirements and the other relevant provisions
of the directives 1999/5/EC and 2004/108/EC.
For EC countries: according to the directive 2012/19/EU for Waste Electrical and Electronic Equipment (WEEE).
Original upon request.
-
BUY
TO
The sensor power is off.
Improper output
confi guration on the sensor.
The sensor is disturbed by
the closing of the door or
vibrations caused by the
door motion.
It rains and the sensor
detects the motion of the
rain drops.
In highly refl ective
environments, the sensor
detects objects outside of its
detection fi eld.
In airlock vestibules,
the sensor detects the
movement of
the opposite door.
-
SELL PRODUCT
Check the wiring and the power supply.
1
Change the output confi guration setting on
1
each sensor connected to the door operator.
Make sure the sensor is fi xed properly.
1
Increase the antenna angle.
2
Increase the immunity fi lter.
3
Reduce the fi eld size.
4
Increase the immunity fi lter.
1
Install the ORA (rain accessory).
2
Change the antenna angle.
1
Decrease the fi eld size.
2
Increase the immunity fi lter.
3
Change the antenna angle.
1
Increase the immunity fi lter.
2