2) Slide the plastic edging out of the longest track section 3 to 4
inches. Next, press the wired device fitting onto the plastic edging
with the cord facing onto the track, then slide the device fitting tabs
into the bottom slot on the track base only an inch or two.
3" - 4"
3) Run the power cord down the length of the raceway and out the
end opposite the device fitting.
Power and Data models only: Add any additional low voltage
wires required by feeding them through the brush on the device
fitting. Insert wire hold-downs (clips) as required (5 provided) to
hold the wires in place.
Wire hold-down (clip)
4) Slide the tabs of the cable exit bracket into the bottom slot on
the track base opposite the device fitting, making sure all the wires
that need to exit the track are passed through the bracket legs.
Cable exit bracket
Alignment
Device
Rails
Fitting
Tabs
User supplied Low-Voltage Wire
5) Make sure the plastic edges are now back in place, pushed tight
against the cable exit bracket. Next attach the covers to the base
starting with the longest cover section abutting the cable exit
bracket.
Install the covers with a rubber mallet or bottom of a rubber coated
hammer handle. Be sure to mount the covers as close together as
possible and touching the cable exit bracket
CAUTION: Risk of Electric Shock! No gaps over 1/16 inch are
permissible.
6) Slide the device box toward the cable exit bracket until it touches
the installed covers. Force maybe needed and a small amount of
shaved plastic edging is normal, the box is intentionally tight to stop
movement.
7) Install the flat end plate onto the end of the track with the
supplied (2) screws to hold the device fitting in place.