iCLASS SE and multiCLASS SE
2
Wiring
Pigtail Reader
Note: Previous iCLASS readers had reversed RS-485 wiring ( P2-7 & P2-6 - A & B). When upgrading to an iCLASS SE reader, ensure proper connections as defined below.
Note: It's possible to reuse existing Wiegand wiring for OSDP, however, using simple stranded cable typical of Wiegand access control readers is usually not meeting the
RS485 twisted pair recommendations.
Note: For OSDP cable lengths greater than 200ft. (61M) or EMF interference, install 120Ω +/- 2Ω resistor across RS-485 termination ends.
Note: Wiring the reader incorrectly may permanently damage the reader.
Pigtail
Terminal
Description
Yellow
P1-1
Beeper Input
Orange
P1-2
LED Input (GRN)
Black
P1-3
Ground (RTN)
Red
P1-4
+VDC
Drain
P1-5
Unused
Brown
P1-6
LED Input (RED)
Blue
P1-7
Hold Input
*
Tamper Output. When activated, output syncs to ground (default).
**
Dependent upon reader configuration.
See HTOG Wiegand and Clock-and-Data configurations for more information.
6
INSTALLATION GUIDE
BEEP
GPI01
GRN
GPI02
GND
OC/TMPR
+VDC
DATA1/CLK
DRAIN
DATA0/DATA
RED
GPI03
HOLD
GPI04
P1
18 in
P2
(0.46 m)
Terminal Reader
Pigtail
Terminal
Red / Green
P2-7
Tan
P2-6
Violet
P2-5
White
P2-4
Green
P2-3
Pink
P2-2
Gray
P2-1
© 2009-2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
RM40, RMP40, RMK40, and RMPK40
c
ableado
c
âblage
f
iação
V
erdrahtung
п
одключение проводов
ELECTROSTATIC SENSITIVE DEVICES
Description
**
GPIO1/OSDP (RS485-FDX/HDX-A)
**
GPIO2/OSDP (RS485-FDX/HDX-B)
*
Open Collector Output / Tamper
**
Wiegand Data 1 / Clock
**
Wiegand Data 0 / Data
**
GPIO3 (RS485-FDX-Z)
**
GPIO4 (RS485-FDX-Y)
PLT-01320, B.5
c
ablaggio
配線
布线
배선
ATTENTION