Strange mist smell
Too little intensity
The mist does not rise
Noise
ADVICE REGARDING THE DISPOSAL OF WASTE
• All the packaging is composed of materials that pose no hazard for the environment and which can be disposed
of at your local sorting centre to be used as secondary raw materials. The cardboard may be disposed of in a
paper recycling bin. The packaging film must be taken to your local sorting and recycling centre.
• When you have finished using the device, please dispose of it in an environmentally friendly way and in accordance with
the law.
LIMITED WARRANTY
LANAFORM® guarantees that this product is free from any defects in materials and any manufacturing defect. This
guarantee is effective for two years as from the date of purchase, except in the following cases:
This warranty on a LANAFORM® product does not cover damage resulting from inappropriate or excessive use, accident,
the use of prohibited accessories, a modification of the product or any other circumstance beyond the control of
LANAFORM®.
LANAFORM® cannot be held liable for any type of unforeseeable, consequential or special damage.
All warranties on well-being products are limited to a total duration of two years as from the date of purchase.
On reception, LANAFORM® will repair or replace your ultrasonic humidifier, as the case may be, and will return it to you
carriage paid. Only a LANAFORM® Service Centre is authorized to implement the guarantee. Any maintenance of this
product by any person other than a LANAFORM® Service Centre voids the guarantee.
Water has been stagnating too long
in the tank
Too much water in the tank
Mist adjustment is set at a minimum
Sediment on the transducer
Water too cold
Water is not clean
The mist intensity is set at minimum
The tank and the base are not
perfectly matched
The fan does not function correctly
Resonance due to a low level of water
in the tank
Resonance due to an unstable surface Place the unit on a stable surface.
Clean the tank and add clean water
Empty water from the tank and put
the tank back
Adjust intensity adjustment knob
Clean the transducer
Use water at ordinary temperature
Clean the tank and add fresh water.
Adjust the intensity.
Correct this.
Ask a professional to verify the
ventilator in the base.
Add water in the tank.