TYPICAL CONNECTION SETUP
1. Connect wires from panels to 3-in-
1 connector.
(Part #1 > Part #7)
2. Connect the 3-in-1 connector to
the 12' Extension Cable.
(Part #7 > Part #3)
3. Splice Charge Controller
Connector and Charge Controller.
(Positive to positive and negative
to negative)
(Part #8 > Part #2)
4. Connect Charge Controller to 12V
battery (not included).
(Part #2 > 12V Battery)
5. Connect the 12' Extension Cable
to the Charge Controller
Connector to start charging the
battery.
(Part #3 > Part #8)
*For 110V-120V AC devices, use the Power Inverter (See steps below)
6. Connect Power Inverter Connector
to the 12V battery.
(Part #6 > 12V battery)
OBSERVE POLARITY.
CONNECT POSITIVE (RED)
CLAMP FIRST.
7. Connect Power Inverter to the 12V
socket on the Power Inverter
Connector.
(Part #9 > Part #6)
Connect the Charge Controller battery positive (+) to the
Controller battery negative (-) post to the negative (-) battery
*Run your 12V DC devices directly from the battery
Part #9
Part #1
Part #7
Part #8
positive (+) battery terminal. Then connect the Charge
Part #3
Part #6
Note: It is strongly recommended to turn off the
inverter when not in use. The inverter's standby
current draw or no load draw is 0.2-0.3A. If the
inverter is not turned off after use, it is possible
to drain an 18 Ahr battery within 3 days.
Part #3
Part #2
OBSERVE POLARITY
terminal.
Part #8