Activated Carbon Filter; Important Safety Instructions - Lanaform Full Tech Filter Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
2) Non-woven mesh filter
This anti-bacterial and anti-mildew filter also picks up large particles and extends the life of the other filters. It collects
dust, pollen, mildew and microscopic organisms.

3) Activated carbon filter

The activated carbon granules trap chemical gases and odours from cigarette smoke as well as organic and kitchen
waste.
4) HEPA filter
This incredibly effective filter traps up to 99.97% of dust, pollen, mildew, bacteria and any other particles carried in the
air smaller than 0.3 microns.
5) Nano cold catalyst filter
This filter effectively decomposes dangerous chemical gases, such as formaldehyde, benzene, ammonia etc.
6) Ioniser
The final stage in the air purification processes involves the release of anions (= negative ions) into the air to increase
air purity.
ODOUR AND DUST SENSORS
The "Full Tech Filter" can automatically detect the levels of odours and dust in the room and adjusts the ventilation speed
accordingly.
THE PRINCIPLE OF "IONISATION:
• The unit produces a large number of negative ions, more commonly known as anions. These electrical charges are
symbolised by a negative sign "–" because of their negative electric charge.
• Volatile particles, such as pollen and allergen-bearing dust, have positive electrical charges.
• The laws of physics tell us that particles with negative charges are attracted to particles with positive charges.
• The negative ions produced by the unit will therefore combine with the positively charged particles, making them
heavier and less volatile. These particles will then fall to the ground and become much less likely to be inhaled.
• Cleaning the floor every day will minimise allergic reactions.
INSTALLING THE AIR PURIFIER:
• Before using the air purifier, remove the protective cover from the filter cartridge at the bottom of the unit.
• Plug in the air purifier to the power.
• When the unit is plugged in, you will hear a sound indicating that the power is working

Important safety instructions:

N.B.:
follow these instructions for the best results from your air purifier.
• Leave at least THIRTY centimetres around all sides of the air purifier.
• Do not put the air purifier next to a fan as this will disrupt normal air circulation.
• Do not put the air purifier near a window or door. This could prevent air from entering or coming out of the unit.
• Make sure you put the air purifier in a well-ventilated area.
• The air will be purified more effectively if the unit is near the source of any pollution.