close it tightly, Items (f) (e).
Finally, correctly place the reservoir on the base of the unit using the markers placed on the back of the humidifier, Items (d,
c) (b, a).
5) Make sure your hands are completely dry when connecting and disconnecting the device and if they are not, then dry them.
6) Press the black switch, Item (h), on the back of the unit to turn it on (-).
7) The humidifier is now working. Turn the knob (Item 4, Figure 1) to set the emission of cool mist.
Light indicator
Meaning
Important notes:
- Only use clean, fresh, distilled or demineralised water to avoid any malfunction.
- Do not pour water into the diffuser sprinkler tip to prevent malfunction and fire risk (Item 1, Figure 1).
- Make sure the reservoir lid is tightly closed after filling so as to avoid leakage or potential electric shocks.
- The reservoir must be kept clean. If the sprinkler tip emitting cold mist is dirty, clean it with a brush or damp cloth.
Please note: EVEN THOUGH THERE IS A SAFETY DEVICE THAT STOPS THE TRANSDUCER
WORKING, DO NOT LEAVE THE DEVICE CONNECTED WHEN YOU ARE NOT USING IT.
Maintenance and Storage (always switch off (o) the humidifier, Item (h) Figure 2):
If the water contains too much calcium and too much magnesium, it may deposit a "white powder" in the device. If this foam
is deposited on the transducer (white ceramic ring emitting ultrasounds (i)), this will prevent the BOREAS humidifier from
working properly.
Maintenance
We recommend:
1) Using clean, fresh, distilled or demineralised water each time it is used.
2) Cleaning the reservoir every 2 days and cleaning the transducer every week.
3) Cleaning the device (see explanations below) and making sure that all its parts are completely dry when it is not in use.
To clean the transducer (white ceramic ring (I)):
1) Put 2 to 5 drops of vinegar on its surface and leave them there for 2 to 5 minutes.
2) Brush the foam off the surface with a soft brush. Do not use a hard tool to scrape the surface.
3) Rinse the reservoir of the base in clean water.
4) Do not use soap, solvent or spray cleaner to clean the transducer.
To clean the water basin:
1) Clean the basin with water using a soft cloth and vinegar if there are foam or limescale deposits on the inside.
2) Rinse the basin in clean water.
To clean the cool mist emission nozzle of the device:
1) Clean this with a brush or damp cloth.
2) Rinse the nozzle in clean water.
Storage:
Having cleaned and dried the device, store it in a dry, cool place out of the reach of children.
6
Red
The device is not working
(see causes below)
Green
The device is working
(there are no issues)