8.

Cleaning and Maintenance

8.1
General
Only perform the maintenance as described in this user manual. Contact an authorised
dealer or service agent for any other maintenance or repair.
If the iron or station becomes faulty or, for some reason does not operate normally,
return it to the service department of your authorized dealer or service agent.
Clean the outer cover of the iron and station with a damp cloth and a small amount of
liquid detergent. Never submerge the unit in liquid or allow any liquid to enter the case
of the station. Never use any solvent to clean the case.
Use only original replacement parts.
8.2
Replacing the Heating Element
Switch off the unit and allow it to cool first.
1.
Loosen the three screws [A] on the hot air gun handle and take off the cover.
2.
Disconnect the grounding wire and pull the heating element out of the stainless
steel tube [B]. Do not damage or lose the quartz glass and/or insulating mica
inside the stainless steel tube.
3.
Place a new heating element in the tube, and reassemble in reverse order [C].
8.3
Storing
Store the appliance, its accessories and this user manual in the original packaging.
Always store in a cool and dry place.