Descargar Imprimir esta página

Samon LT-aSENSE-5000-R Manual De Instrucciones página 6

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

GB
FEATURES
Non-Dispersive Infrared (NDIR) technology
Internal automatic self diagnostics
Maintenance interval > 5 years
Cost-efficient RS485 or LonWorks local network
communication as options
GENERAL
LT-aSENSE-5000-R is a detector for measuring the
concentration of carbon dioxide in cold storage. It contains a
special heat source that enables the detector to function in
o
temperatures down to -30
C. The display (option) shows the
momentarily concentration plus an average value that is time
weighed for the latest eight hours, a so-called TWA-value.
The relay of the CO
-concentration is calibrated so that it closes
2
at 2000 ppm and opens again at 1800 ppm.
FUNCTION
LT-aSENSE-5000-R is a microprocessor based carbon dioxide
transmitter for installation in cold storage. The detector
measures the concentration continuously and the analogue
output is proportionate to the concentration. The automatic
calibration (ABC-function) is the key for maintenance free
operation. The condition is normal indoor environment, or
applications where some kind of ventilation exists (minimum
some sort of ventilation during a 7 day period).
MAINTENANCE
In normal installations the LT-aSENSE is maintenance free if
the automatic calibration (ABC) is activated. An inspection of
the transmitter every year is recommended.
Equipment for zero (0)-calibration is available.
WIRING DIAGRAM
INSTALLATION
See installation instructions.
Specifications subject to change.
IS LT-aSENSE 0711.doc
LT-aSENSE-(CO
Standard configuration of LT-aSENSE transmitter outputs
LT-aSense- 5000
Terminal
1 (G+)
2 (GO)
3 (OUT.1)
4 (OUT.2)
5 (M)
6
7
8
NB! The detector has a built-in heater and the
current consumption can amount to 2A. Choose
power unit with regards to this.
This product is in conformity with
the EMC-directive 89/336/EEC.
It fulfils the requirements of:
SS-EN 50 081-1, ed. 1 1992
SS-EN 50 082-2, ed. 1 1995
6
)
2
(0-5000ppm)
Standard
Standard settings
Configuration
Supply (+)
Supply (-)
0-10 VDC
0-5000 ppm (CO
o
0-10 VDC
0-50
Signal ground (-)
Relay, normally
Closes at 2000ppm
open
Opens at 1800ppm
)
2
C

Publicidad