Technical Data
Command box to monitor NAVILITE 48Vdc
P/N113900, 113905 or 113965
Input voltage
INSTALLATION INSTRUCTIONS -
NOTICE D'INSTALLATION -
NOTICIA DE INSTALACIÓN -
Connexion
INSTALLATIONSHINWEISE -
Attachment
ISTRUZIONI PER L'INSTALLAZIONE
- INSTRUCOES DE INSTALACAO -
Cable diameters
MONTÁŽNÍ NÁVOD -
-
Alarm conditions
安装指导书
IT07018_D
Setting of
the switches
3
2
Lamp2
Lamp1
Alarm
Synchro
1
12-24Vdc (+15%/-10%)
48Vdc (+15%/-10%)
120-230Vac (+/- 10%)
By terminal connexion, wire cross section up to 2,5m²
By 4 M3 screws 148x150 mm
- For lamps 5 to 10 mm
- For supply & signal 7 to 13 mm
- Power supply failure
- Lamp failure
To reset alarm, switch o ,
then switch on again after one minute
Night only operation
or
Permanent operation
(censor activated)
Number and con guration of NAVILITE :
or
1 - 4 simultaneous
« 1+1 » or « 2+2 » or « 3+3 »
or « 4+4 »main and back-up
1. Set the switches
1
ON
ON
1
2
3
4
5
6
1
2
1-1 :
OFF
ON
ON/Reset
1-2 :
Light Sensor
ON : Night only
OFF : day & Night
1-5: main and back-up / simultaneous
ON : 1st main &2nd back-up
OFF : 1st & 2nd simultaneous
Dimensions
P/N
101
2. Connect the navilite-48V
2
2 Navilite 48V "main and back-up"
Main
3
4
5
6
7
8
OFF
1-6 / 2-1 / 2-2 :
Number of lights
1-6
2-1
2-2
1 Navilite O F F O F F
O F F
2 Navilite O F F O N
O F F
3 Navilite O F F OFF
O N
4 Navilite O N
O N
O N
Installation
5.5
+ 55°C
- 40°C
160
M3x16
1 to 4 Navilite 48V
working simultaneously
Back-up
LAMP1
LAMP2
Alarm
Input voltage
Alarm
Input voltage
Navilite
48 Vdc
Bracket
113920
Command
card
M3 nut
LAMP1
LAMP2
Junction
Junction
Junction
box
box
box
Next step

Publicidad

loading

Resumen de contenidos para obsta NAVILITE 48Vdc

  • Página 1 Technical Data Dimensions Installation Navilite Command box to monitor NAVILITE 48Vdc + 55°C 48 Vdc P/N113900, 113905 or 113965 - 40°C Bracket 12-24Vdc (+15%/-10%) 113920 48Vdc (+15%/-10%) Input voltage INSTALLATION INSTRUCTIONS - NOTICE D’INSTALLATION - 120-230Vac (+/- 10%) NOTICIA DE INSTALACIÓN - Connexion By terminal connexion, wire cross section up to 2,5m²...
  • Página 2 - Si raccomanda vivamente la protezione dalle sovratensioni. - Per la scelta dell’installazione seguire le racccomandazione www.obsta.fr / www.obsta.de / dell’Annex 14 della norma ICAO. www.obsta.us / www.obsta.com / www.obsta.ru - La temperatura operativa deve essere inferiore a 55°C. 2, rue Troyon, 92316 Sèvres CEDEX France...