RX2-XL
ON
1
2
3
4
5
6
7
8
L3
1
2
3
4
5
OUT 2
► CONNECTION OF THE RECEIVER
POWER SUPPLY (3 and 4). The receiver can be powered from
12 to 24 volt in AC and DC as well. The polarity must be used in
case of DC (positive on clip nr. 4).
ANTENNA (1 and 2). The antenna must be connected with
positive (the spirit) on the contact no.1 and negative (stocking).
If only one is used (17cm for freq. 433,92 Mhz - 8.5 cm for freq.
868 Mhz), this has to be connected to contact n°1.
OUTPUT (from 5 to 9). The normally opened rele´of exit 1 is
on contact n° 7 and 8 while the normally closed contact is on
contact n° 8 and 9. For output 2 the normally opened contact
is present only on clips n° 5 and 6. It is recommended not to
connect such contacts to high tension and to make sure that the
current not exceed 1 ampere.
► USE OF RECEIVER
WARNING!!! IT IS NECESSARY TO EXECUTE
THE MEMORY´S RESET!!!
RESET PROCEDURE
RESET PROCEDURE
This operation cancels all codes in the memory. It is necessary
to execute the memory´s reset before learning the fi rst TX, so
that the previously codes and the code that are not used, are
not in the memory:
1.
Make sure that the output are deactivated
(The green led L1 and L2 are turned off).
2.
Make sure that the receiver is not learning. The red led L3
must be switched off.
3.
Keep pressed the button P1 till the red led it is switched on.
(10 seconds) and then release it.
4.
Wait that the red led will be switched off or fl ashing.
4 Channel receiver with self-learning, it manages standard
codes from 12 till 80 and rolling HCS© or rolling EB
► PROGRAMM DIP:
Removable
memory
DIP 1
DIP 2
P1
P2
DIP 3
DIP 4
L2
L1
DIP 5
DIP 6
DIP 7
DIP 8
6
7
8
9
► CODE'S MEMORIZATION
LEARNING OF A TRANSMITTER
1.
2.
OUT 1
3.
4.
TRANSMITTER'S CANCELLATION
(not fot EB rolling).
This function can cancel only one single remote
control:
1.
2.
3.
4.
DEACTIVATION OR ACTIVATE OF ONE REMOTE
CONTROL (for Eb rolling).
The deactivation of one single remote control
is useful in case the automatic memorization is
always activate (DIP5 ON) and it doesn't need to be
memorized when the signal will be received. This
procedure is useful in case to invert the managing of
the remote control, if It was activated or deactivated,
and if it was deactivated, it will be activated:
1.
2.
3.
4.
ON
EB Rolling code function activated
ON
HCS rolling code function activated
ON
Reduce the output activation from 0.8 to 0.3 s
The receiver will accept only the same type of code of the fi rst memorized remote controls, the next
The receiver will accept only the same type of code of the fi rst memorized remote controls, the next
ON
one should have the same type of code.
If you are using the HCS rolling code function, DIP 2 in ON, keep pressed button 1 and 2 of the
remote control which has been already memorized, the codes learning is in the OUT1. If you are
ON
memorizing EB rolling code, DIP1 ON, you activate the self-memorization of the remote controls
with the same installation code.
ON
Excluding the step-by-step function on the time outputs.
ON
It activate the managing of the inverted code (differential Manchester encoding)
ON
Not used
Make sure the exit´s receivers are not in use
and not in learning the green led (L1 and L2)
are turned off.
Push
and
release
the
push-botton
corresponding to the exit of the remote control,
P1: OUT1 or P2: OUT2
The green led associated will lit on
Press the transmitter's button within 5
seconds. If the code has been learnt, the red
led fl ashes fast for 2 seconds. If the red led
fl ashes slowly it means that the memory is full.
If the red led doesn't fl ash it means that the
transmitter is not compatible.In order to learn
other codes on the exit 1 repeat operation 1.
Press and keep pressed the buttons P1 and
P2
Press the button of the remote control which
code need to be cancelled
Led L1 and L3 fl ash briefl y to confi rm the
cancellation of the code
Release all buttons
Press for 2 seconds and then release the
buttons P1 and P2 on the control board
Press the button of the remote control. Se
questo è in memoria il led relativo all'uscita
inizierà a lampeggiare.
If the code is activated it will be deactivated
and vice versa.
If the buttons P1 and P2 will be pressed
for more than 5 seconds, the code will be
cancelled from the memory of the receiver
MEMORY CODES´S CAPACITY
The receiver is in a position to manage till 190 transmitters
rolling (till 4 channels for transmitter) and till 190 transmitters
with standard code (1 channels for TX).
TYPE OF CODES´S MANAGE.
This receiver is in a position to manage the standard codes
from 12 to 80 bit and rolling codes type HCS© or Rolling EB.
DESCRIPTION OF THE EBR CODE
The EBR code is a rolling code and it cannot be copied.
Each EBR remote control has its own production code which
cannot be changed. Moreover the EBR code is composed of
an installation number which can be programmed from the
installer. This installation number is important for the EBR
receiver to know if it can be automatically memorized or not.
If a EBR remote control has been already memorized with the
same installation number, it is not necessary to learn it in the
receiver.
► FUNCTIONS
FUNCTION STEP BY STEP
The receiver´s exit can be made also used for the operation
step by step. To active or disactive the operation it is suffi cient
to push the button when only the relative exit is active (green
led switched on, L1: OUT1 and L2: OUT2). If the exit was in
normal, the operation step by step will be operating, while if
the following operation was already active, the exit will return
to the normal function.
FUNCTION STEP-BY-STEP WITH TIMING.
The output works as the step-by-step mode (DIP 6 OFF)
with a self-deactivation after a planned time. To activate this
function the receiver must be in normal function (not step-by-
step or step-by-step with timing) so when the output has been
activated:
1.
Press the button in the receiver corresponding to the
output until the led start fl ashing and then release the
button.
2.
The green led fl ashes, L1: OUT1 or L2 OUT2.
3.
Let the time goes for maximum 512 seconds for the
timing and then press the button again.
4.
To deactivate the function step-by-step with timing, it
is suffi cient to press the button in the receiver to the
corresponding output when the output is activated.

Publicidad

loading