Installation
Installation
Surface-Mounted Towel/Waste Unit
NOTE: For semi-recess and recess-mounted unit, refer to the instructions on page 1.
IMPORTANT: Adequate in-wall backing must be provided by installer to fully support the
weight of the unit. Always check local codes and ordinances prior to installation.
IMPORTANT: Concealed mounting holes in back of the unit must be provided by installer
prior to installation. Refer to Figure 2 for suggested mounting hole locations.
1. Plaster or dry wall construction: Provide in-wall backing (suitable for use with #10 x 1"
screws) at the mounting slot locations shown in Figure 2 below.
Other wall surfaces: Provide fiber plugs or expansion shields (suitable for use with #8 x 1-1/4"
sheet-metal screws supplied by installer), OR provide 1/8" toggle bolts or expansion bolts. If
installing where unit projects above top of wainscot, provide aluminum channel or other filler to
prevent gap from finished wall to back of unit. For block walls, use metal expansion shields
(provided by installer).
2. Unlock the door and remove the waste can. Secure the unit to the wall through the concealed
mounting holes (provided by installer) with the hardware appropriate for your wall construction.
Figure 2
56"
(1423mm)
8-1/2"
(216mm)*
* Suggested mounting hole
locations for installer
Bradley Corporation • P20-164; EN 05-1512
51"
(1295mm)*
2-1/4"
(57mm)*
14-13/16"
(376mm)*
4" TYP
(102mm)
42-1/2"
(1080mm)
CENTERLINE
OF BACKING
17-1/8"
(435mm)
3/9/05
227
CENTERLINE
OF BACKING
TO FLOOR
5'-0" MIN
(1524mm)
TO
6'-3" MAX
(1905mm)