FX40D
CONNECTIONS
Automation
central unit
FUNCTIONING CHANNEL
The channel (Channel A or Channel B) is selected by a configuration
jumper and prevents the possibility of interference between two couples of
photocells that are operate in the same working area (for ex. Installation of two
couples of photocells on sliding gate).
After installation
Check that there is no voltage.
Wait approx 15 seconds to make the condensers unload.
Select a couple of photocells on the Channel A for the other couple
choose the Channel B using JMP1 as in figure.
Supply power to the photocell.
In this way, also if illuminating the receiver Rx2, the photocell Tx1 never realizes the alignment
condition because Tx1 and Rx2 are configured on two different functioning channels.
The same condition is valid for Tx2 and Rx1.
Rx 2
Rx 1
RECEIVER LED FUNCTIONING (Rx)
The GREEN signalling LED indicates the alignment status:
GREEN LED on: absence of obstacles (aligned infrared beam).
GREEN LED off: presence of obstacles (not aligned infrared beam).
TRANSMITTER LED FUNCTIONING (Tx)
The RED signalling LED indicates the correct functioning of the selected channel:
RED LED with fixed off or fixed on light: transmitter module in failure.
RED LED with quick flashing: transmitter module functioning on channel A.
RED LED with slow flashing: transmitter module functioning on channel B.
4
NOTE: If JMP2 is selected
on 12,5 Vdc ±5% connect
the photocells on 12Vcc
of the controls station
Channel A
Channel B
To use the JMP2 in order to
select the type of tension
JMP1
Channel A
CH.A CH.B
Tx 2
Tx 1
12,5Vdc ±5%
JMP2
12/ON - 24/OFF
24V~ ±5%
JMP2
12/ON - 24/OFF
Channel B
CH.A CH.B