Technical parameters

Supply
Supply terminals:
Voltage range:
Supply voltage tolerance:
Power input (apparent / loss):
Setting function
Function - :
Function - :
Set. the scale of relative humidity
- range 1:
- range 2:
- range 3:
Slight setting of relative humidity:
Hysteresis
Hysteresis setting:
Output
Number of contacts:
Current rating:
Breaking capacity:
Inrush current:
Switching voltage:
Mechanical life:
Electrical life (AC1):
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Protection degree:
Overvoltage category:
Pollution degree:
2
Max. cable size (mm
):
Suggested power-supply cable:
Dimensions:
Weight:
Standards:
RHV-1
L - N
AC 230 V / 50 - 60 Hz
- 15 % .. +10 %
max. 6 VA / 0.7 W
setting function Jumper J3
moistening
drying
humidity setting Jumper J2
0 .. 30 % RH
30 .. 60 % RH
60 .. 90 % RH
potentiometer
2, 3, 4 % from setup rate
Jumper J1
1x NO-SPST (AgSnO
)
2
12 A / AC1
3000 VA / AC1, 384 W / DC
30 A / < 3 s
250 V AC / 24 V DC
3x10
7
0.7x10
5
-30 °C .. 60 °C (-22 °F .. 140 °F)
-30 °C .. 70 °C (-22 °F .. 158 °F)
4kV (supply-output)
sensor-side down
IP65
III.
2
max. 1x 2.5, max. 2x 1.5 /
with sleeve max. 1x 2.5 (AWG 12)
CYKY 3x 2.5 (CYKY 4x 1.5)
153 x 62 x 34 mm (6˝ x 2.4˝ x 1.3˝)
148 g (5.2 oz.)
EN 60730-2-9, EN 61010-1
Function
actual humidity level
setup relative
humidity level
L - N
15 - 18
15 - 18
Warning
The device is constructed to be connected into 1-phase main and must be installed in
accordance with regulations and norms applicable in a particular country. Installation,
connection and setting can be done only by a person with an adequate electro-technical
qualifi cation which has read and understood this instruction manual and product
functions. The device contains protections against over-voltage peaks and disturbing
elements in the supply main. Too ensure correct function of these protection elements
it is necessary to front-end other protective elements of higher degree (A, B, C) and
screening of disturbances of switched devices (contactors, motors, inductive load etc.) as
it is stated in a standard. Before you start with installation, make sure that the device is
not energized and that the main switch is OFF. Do not install the device to the sources of
excessive electromagnetic disturbances. By correct installation, ensure good air circulation
so the maximal allowed operational temperature is not exceeded in case of permanent
operation and higher ambient temperature. While installing the device use screwdriver
width approx. 2 mm. Keep in mind that this device is fully electronic while installing.
Correct function of the device is also depended on transportation, storing and handling.
In case you notice any signs of damage, deformation, malfunction or missing piece, do
not install this device and claim it at the seller. After operational life treat the product as
electronic waste.