DOOR ENTRY SYSTEMS
SETTING TIMES FOR DOOR OPENING FROM INSIDE - 2-WIRE SYSTEM
39
CC1
30
Push-button
Note: To connect the door entry system, look up in the technical datasheet that
comes with the audio unit.
Operation
When the pushbutton is pressed, the circuit of the control signal (15Vdc) is closed through
this pushbutton, allowing the circuit between terminals 22 and 18 to be closed and for power
to be supplied to the electric lock for a pre-established period of time (see timing in adjusting
instructions).