Special Application: Finding Shorts
Set-up:
1
Transmitter
Verify the
Loop LED
is ON.
1. Connect the Transmitter with the test leads
to the circuit.
2. Switch the Transmitter to Loop mode by
short press of On/Off button. Verify that the
Loop LED is ON.
Tracing mode:
Tracing a cable to find shorts
1. Start tracing the cable until the signal stops.
2. Verify the place of the fault: move the
Transmitter to the other end of the wire and
repeat tracing from the opposite end. If the
signal stops at the exact same location the
fault has been located.
Note:
by signal cancellation effect. Expect
a relatively weak signal.