GA3450TA ThermosTAT Blower Accessory
For use on CGCF, VMH26, VMH10, FMH26, and FMH10 Series
Compact Fireplaces and CF26 Series Bayfront Fireplaces
WARNING: Fan accessory must be grounded. Fan
comes with a three-prong, grounding plug as shown in
Figure 1. The plug is your protection against electrical
shock. Plug it into a standard, three-hole, grounded,
outlet. If cord needs replacing, use only a cord with a
three-prong, grounding plug.
NOTICE: Cord length from switch plate assembly to
plug is six feet. Make sure grounded outlet is an ap-
propriate distance from unit.
WARNING: Failure to connect all wires as indicated
may cause electrical shock or personal injury.
CAUTION: Verify proper operation after servicing.
Grounded Outlet
Figure 1 - Grounding Plug
INsTAllATIoN INsTrUcTIoNs
Grounding Plug
REMOVING UPPER LOUVER ASSEMBLy
To install blower accessory, you must first remove the upper
louver assembly.
All Models Except CF26 Series
1. Remove 4 brass-plated screws from louver assembly
(see Figure 2). Save these screws.
2. Pull louver assembly straight out from the cabinet. Be
careful not to scratch the paint. Set louver assembly and
screws aside.
Figure 2 - Removing Upper Louver Assembly
STANdARd INSTALLATION
Removing Valve Cover Shield
1. Open bottom louver assembly by swinging the assembly
down (see Figure 3, page 2).
2. Using short Phillips screwdriver, remove screw under
the center of branch support. Rotate valve cover shield
clockwise and slide out. IMPORTANT: Do not remove
shoulder screw on left side of valve cover shield. Slide
valve cover shield off of shoulder screw (see Figure 3,
page 2).
Note: If you do not have a short Phillips screwdriver, the
screen, twigs, and branch support must be removed so a
longer screwdriver may be used. Follow directions in the
owner's manual for screen and twig removal/installation.
Branch support may be removed by removing 2 screws
on each side of support.
www.desatech.com
Blower Bracket
Mounting Holes
Upper Louver
Assembly

Publicidad

Tabla de contenido
loading

Resumen de contenidos para DESA Heating Products GA3450TA

  • Página 1 GA3450TA ThermosTAT Blower Accessory INsTAllATIoN INsTrUcTIoNs For use on CGCF, VMH26, VMH10, FMH26, and FMH10 Series Compact Fireplaces and CF26 Series Bayfront Fireplaces REMOVING UPPER LOUVER ASSEMBLy WARNING: Fan accessory must be grounded. Fan To install blower accessory, you must first remove the upper comes with a three-prong, grounding plug as shown in louver assembly.
  • Página 2 Wiring Routing Blower Bracket Hole in Baffle Assembly Baffle Screw Shoulder Screw Remove Valve Cover Screw Shield Wire Switch Harness Power Cord Snap Bushings Bottom Louver Branch Support Assembly Blue Red Figure 3 - Removing Valve Cover Shield Switch Plate Installing Blower Assembly Note: If you are using a mantel with your heater, use the fol- Valve...
  • Página 3: Extension Cord

    FOR BUILT-IN INSTALLATION WARNING: A licensed electrician must connect the wiring harness to electrical supply following all local codes. Electrician must provide a clamp on the box cover to secure the wiring. Wiring should be routed through the bushing in the hole on the outer casing of heater.
  • Página 4 OPERATING FAN This blower has three settings: ON, OFF, and AUTO. In the ON position, the blower will operate constantly. In the OFF position, the blower will not operate. In the AUTO position, the blower will start when the thermostat senses a sufficient increase in firebox temperature.
  • Página 5: Extracción Del Conjunto De Ventila Superior

    GA3450TA Accesorio venTilAdor del TermosTATo insTrUcciones de insTAlAciÓn Para usarse con las chimeneas compactas serie CGCF, VMH26, VMH10, FMH26 y FMH10, así como con las chimeneas Bayfront serie CF26 ExTRACCIÓN DEL CoNjUNTo DE VENTILA ADVERTENCIA: el ventilador debe estar conectado sUPERIoR a tierra.
  • Página 6 Nota: si no cuenta con un destornillador Phillips corto, 9. Instale la placa del interruptor en la cubierta de protección se deben quitar la rejilla, los leños y el soporte de leños, de la válvula utilizando 2 tornillos #10 incluidos (consulte para poder utilizar un destornillador mas largo.
  • Página 7: Para Instalación Empotrada

    PARA INsTALACIÓN EMPoTRADA 4. Un electricista con licencia debe segur el diagrama de conexiones para conectar la alimentación eléctrica entrante al conjunto de cables del juego de ventilador ADVERTENCIA: un electricista con licencia es el que (consulte la figura 7). debe conectar los arneses del cableado a la alimenta- ción eléctrica siguiendo todos los códigos locales.
  • Página 8: Cable De Extensión

    CABLE DE ExTENsIÓN Interruptor Auto/Off/On (automático/apagado/encendido) Utilice un cable de extensión en caso que lo necesite. El cable debe tener una clavija de tres patas con conexión a tierra y un enchufe de tres orificios. Compruebe que el cable esté en buen estado.

Tabla de contenido