Efapel 21234 Manual Del Usuario página 16

Tabla de contenido

Publicidad

FUNCTIONING
1 - Control by Internal Ambient Sensor - Temperature control
is performed by equipment's ambient temperature sensor. In
this operating mode, the sensor will also perform Anti Freeze
Protection (5ºC) and Thermal Protection (35ºC).
2 - Control by Internal Ambient Sensor + Floor Temperature
Sensor - Temperature control is performed by the equipment's
ambient temperature sensor while the floor probe will prevent
floor overheating/overcooling, preventing the floor temperature
from exceeding the defined maximum temperature limits
(Thermal Protection at 35ºC) and minimum (Anti-Condensation
Protection at 16ºC).
When the device is switched ON without a floor probe, it
defaults control mode of "Room sensor without a probe".
At this moment, the LED light flash sequentially (Red-Blue-Red-
Blue). If the floor probe is turned OFF, or if there is a reading
interruption, the LED light starts to flash, indicating the existence
of a problem.
16

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

45234 s

Tabla de contenido