connector (¼ inch NPT threads) with an inner
diameter of 8mm (0.315 inch) to the nailer and a
3/8 inch quick connector to the air hose.
1. Switch the ON/OFF switch on the compressor
the socket.
2. Connect the pressure regulator by turning it
3. Connect the air hose to the pressure regulator.
Turn the valve on the pressure regulator to the
right to a pressure of between 70 PSI and 110
PSI.
PROBLEM
There is a leak at the top of
the device or in the trigger
area.
There is a leak underneath
the device.
The device is not working or 1.
Nails are jamming
frequently.
23
www.DeubaXX L . de
POTENTIAL CAUSE
1. Loose screws.
2. Broken or damaged
O-Rings or seals.
1. Loose screws.
2. Broken or damaged
O-Rings or seals.
2.
3. The vents are blocked.
4. The O-Rings or seals are
worn
1. The driver is worn.
2. he piston is damaged or
worn.
3. Nails are bent.
4. There is dirt in the
magazine.
5. The magazine is loose.
6. Incorrect nails are used.
4. Load the nails into the nail gun.
5. When doing this, make sure you point the nail
6. The nail unit is ready. You may need to change
the pressure for the right drive depth.
SOLUTION
1. Schrauben anziehen
2. Überholsatz installieren
1. Schrauben anziehen
2. Überholsatz installieren
1. Set the compressor to between 70
PSI and 110 PSI.
2. Apply 2–3 drops of oil to the
3. Clean the vents.
4. Fit replacement parts.
1. Repair the driver.
2. Replace the piston.
3. Remove bent nails and replace with
straight nails.
4. Clean the magazine.
5. Tighten the screws.
6. Replace with the correct nails.