Mains voltage
Power input
Idling speed
Max. useful grinding wheel
diameter
Grinding wheel dimensions
Tilting range
Carbide-tipped saw blade
Protection class
Protection type
Weight
Sound and vibration
Sound and vibration values were measured in accordance with EN
61029
LpA sound pressure level
KpA uncertainty
LWA sound power level
KWA uncertainty
Wear ear-muffs
The impact of noise can cause damage to hearing.
S3 50%: intermittent mode, no start-up, no braking (cycle duration 15
minutes). In intermittent mode, the percentage load factor (50%) is
always quotes so that the heat generated during this period can be
dissipated during breaks in operation by convective cooling.
Intermittent mode consists of the on time and the cooling breaks,
known as the duty cycle. The period of consideration is 15 minutes.
50% load factor means that the electric tool can be operated for 7.5
minutes at the rated performance, followed by a cooling phase of
7.5 minutes.
F.
Before starting the equipment
Before you connect the equipment to the mains supply make sure that
the data on the rating plate are identical to the mains data.
Always pull the power plug before making adjustments to the equipment.
4
230 V – 50Hz
110 W S3 50% 15 min.
5300 min. ¹
Ø 100 x Ø 20 x 0,8 mm
-25° + 25°
Ø 16-32 mm Ø 90-350 mm
89,4 dB (A)
100,4 dB (A)
GB
103mm
II
IP 20
4,8 Kg.
3 dB