Figure / Figura 1
Figure / Figura 1
For 16TR/30TR
Figure / Figura 5
TRANSFORMER INSTALLATION INSTRUCTIONS
Figure / Figura 5
IMPORTANT: READ ALL INSTRUCTIONS BEFORE INSTALLING TRANSFORMER.
TRANSFORMER INSTALLATION INSTRUCTIONS
CONTACT A QUALIFIED ELECTRICIAN IF THERE ARE ANY QUESTIONS AS TO THE SUITABILITY OF THE SYSTEM.
1. WARNING: TURN OFF POWER AT FUSE OR CIRCUIT BREAKER BEFORE INSTALLING TRANSFORMER.
IMPORTANT: READ ALL INSTRUCTIONS BEFORE INSTALLING TRANSFORMER.
2. Locate or install a junction box close to the selected mounting location for your chime. Do not install transformer in an
attic location. For new installation remove cover plate and knockout from junction box.
CONTACT A QUALIFIED ELECTRICIAN IF THERE ARE ANY QUESTIONS AS TO THE SUITABILITY OF THE SYSTEM.
3. Mounting locknut type transformer (Model 122): From exterior of junction box, pass transformer wires through hole
1. WARNING: TURN OFF POWER AT FUSE OR CIRCUIT BREAKER BEFORE INSTALLING TRANSFORMER.
in junction box. To secure transformer to junction box, fasten locknut to transformer's threaded shaft on inside of junction
2. Locate or install a junction box close to the selected mounting location for your chime. Do not install transformer in an
box (see Figure 1).
attic location. For new installation remove cover plate and knockout from junction box.
Mounting clamp type transformer (Model 125): Note: Mounting clamp requires a junction box with flat sides and
3. Mounting locknut type transformer (Model 122): From exterior of junction box, pass transformer wires through hole
knockouts. From exterior of junction box, pass transformer wires through knockout hole in junction box. Insert transformer
in junction box. To secure transformer to junction box, fasten locknut to transformer's threaded shaft on inside of junction
clamp through same knockout hole as wires. Tighten screw (provided) against edge of knockout hole on junction box
box (see Figure 1).
(see Figure 2).
Mounting clamp type transformer (Model 125): Note: Mounting clamp requires a junction box with flat sides and
4. Connecting Transformer Wires to Power Wires: If necessary, strip 1/2" of insulation from power supply wires (see
knockouts. From exterior of junction box, pass transformer wires through knockout hole in junction box. Insert transformer
Figure 3). Twist black wire lead from transformer to black wire lead from power supply. Twist white wire lead from trans-
clamp through same knockout hole as wires. Tighten screw (provided) against edge of knockout hole on junction box
former to white wire lead from power supply. Twist green ground wire from transformer to bare (or green insulated)
(see Figure 2).
copper lead of power supply. For metal junction boxes, it is required to connect green ground wire from transformer to
4. Connecting Transformer Wires to Power Wires: If necessary, strip 1/2" of insulation from power supply wires (see
the metal junction box or clamp it to the metal conduit.
Figure 3). Twist black wire lead from transformer to black wire lead from power supply. Twist white wire lead from trans-
Insulate each connection using UL Approved wire nut (see Figure 4).
former to white wire lead from power supply. Twist green ground wire from transformer to bare (or green insulated)
5. Check all connections and replace cover plate.
copper lead of power supply. For metal junction boxes, it is required to connect green ground wire from transformer to
6. Attach low voltage wires from chime, bell, or buzzer to secondary screw terminals on transformer (see wiring diagram
the metal junction box or clamp it to the metal conduit.
included with the chime, bell, or buzzer) (see Figure 5).
Insulate each connection using UL Approved wire nut (see Figure 4).
For 3TRAN
For Model 125 Only: See arrow markings on transformer to determine correct screw terminals for 8, 16, or 24 volt
5. Check all connections and replace cover plate.
connection (see Figure 6).
6. Attach low voltage wires from chime, bell, or buzzer to secondary screw terminals on transformer (see wiring diagram
TO REPLACE EXISTING TRANSFORMER, FOLLOW INSTRUCTIONS ABOVE (OMIT STEP 2). LABEL WIRES PRIOR
included with the chime, bell, or buzzer) (see Figure 5).
TO REMOVAL OF EXISTING TRANSFORMER.
For Model 125 Only: See arrow markings on transformer to determine correct screw terminals for 8, 16, or 24 volt
connection (see Figure 6).
© 2016 HeathCo LLC
TO REPLACE EXISTING TRANSFORMER, FOLLOW INSTRUCTIONS ABOVE (OMIT STEP 2). LABEL WIRES PRIOR
TO REMOVAL OF EXISTING TRANSFORMER.
© 2016 HeathCo LLC
© Newhouse Lighting
P.O. Box 90045
Bowling Green, KY 42102-9045
P.O. Box 90045
Bowling Green, KY 42102-9045
Figure / Figura 2
8V 10VA
Figure / Figura 2
8V 10VA
FOLLOW ALL NATIONAL AND LOCAL ELECTRICAL CODES.
FOLLOW ALL NATIONAL AND LOCAL ELECTRICAL CODES.
Model:
3TRAN/30TR/16TR
16V 10VA
8V 10VA
LOAD
LOAD
24V 20VA
24V 20VA
16V 10VA
8V 10VA
8V 10VA
16V 10VA
Figure / Figura 6
LOAD
LOAD
24V 20VA
24V 20VA
8V 10VA
16V 10VA
Figure / Figura 6
1/2"
Figure / Figura 3
1/2"
Figure / Figura 3
Figure / Figura 4
Figure / Figura 4
16V 10VA
8V 10VA
16V 10VA
LOAD
24V 20VA
16V 10VA
8V 10VA
16V 10VA
24V 20VA
LOAD
24V 20VA
24V 20VA
newhouselighting.com
208431-03
208431-03

Publicidad

loading

Resumen de contenidos para NEWHOUSE HARDWARE 3TRAN

  • Página 1 (see Figure 5). Insulate each connection using UL Approved wire nut (see Figure 4). For 3TRAN For Model 125 Only: See arrow markings on transformer to determine correct screw terminals for 8, 16, or 24 volt 5.
  • Página 2 Aísle cada conexión usando un conector de alambre aprobado por UL (vea Figura 4). Sólo para el Modelo 125: Vea las marcas de las flechas en el transformador para determinar los terminales correctos Sólo para el 3TRAN: © 2016 HeathCo LLC 208431-03 S del tornillo para la conexión de 8, 16, o 24 voltios...

Este manual también es adecuado para: