Lights of America 9700LED Serie Manual Del Usuario página 2

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Wiring the Light COntrOL
Warning: turn power off at circuit breaker
or fuse.
1. Remove the existing light fixture.
2. Install the mounting strap as shown using two
screws that fit your junction box.
3. The plastic hanger can be used to hold the fixture
while wiring. The small end of the plastic hanger
can be threaded through the hole in the center
of the cover plate. The small end then goes into
one of the slots on the mounting strap.
4. Route the light control's wires through the large
gasket holes.
5. Twist the junction box wires and fixture wires to-
gether as shown. Secure with wire connectors.
Black to Black
Mounting
Strap
Junction box ground wire to green ground screw
on fixture.
White to White
Rubber Plug
Gasket
Mounting Bolt
mOunt the Light COntrOL
1. Align the light control cover plate and cover plate
gasket. Secure with the mounting bolt.
2. Align the three slots in the decorative shell with
the lamp holder pins. Push the shell in and then
twist clockwise to lock. Repeat for other shell.
Shell Slot
3. Push the rubber plug firmly into place.
4. If a wet location junction box was not used,
caulk the wall plate mounting surface with
silicone weather sealant.
To avoid water damage and electrical shock,
keep lamp holders 30° below horizontal.
Lock Nut
Lens
5. Adjust the lamp holders by loosening the lock
nuts but do not rotate the lamp holders more than
180° from the factory setting. When screwing in
the flood lamps, do not overtighten.
2
Keep lamps at
least 1" (25 mm)
from the sensor.
Do not allow the
lamps to block
the lens.
598-1360-00

Publicidad

Tabla de contenido
loading

Productos relacionados para Lights of America 9700LED Serie

Tabla de contenido