FEATURES
PumpBody:
Diaphragm:
Valves:
Motor:
Receiver:
BatteryLeads:
SuctionTube:
Weight:
OPERATING INSTRUCTIONS
1.
Run the engine for approximately 5 minutes to
heat oil to approximately 160°F (71°C), then shut
off engine prior to oil removal.
2.
Insert 1/4" (6 mm) tube into pump inlet port and
be sure that it is securely in place.
3.
Open the vent cap located on hose retainer
strap, vent cap must be opened to allow tank to
vent air.
4.
With the pump switch in the off position (to
avoid sparks), clamp the power-leads' alligator
clips to a 12V DC battery (red to positive; black
to negative).
5.
With the engine off, remove the dipstick, and
insert the 1/4" (6 mm) oil change probe through
the dipstick tube until it contacts the bottom of
the oil pan. It may help to measure the probe
against the dipstick, add an inch and mark the
probe. Do not push the probe too far into the
dipstick tube or it may curl up and out of the oil.
It may be useful to tape the probe in place dur-
ing evacuation.
6.
To evacuate the oil, switch on the pump using
the rocker switch at the rear of the motor.Watch
for flow in the probe. If no flow appears in 15
seconds, check the probe for sediment block-
age. Clean the probe and reset it 1/4" (6 mm) off
the pan bottom.
7.
The pump will speed up when the oil has been
removed. An average 5 Quart (5 liters) oil capac-
ity engine will take around 10 minutes to drain.
8.
Switch off pump before removing alligator clips
from the battery, to avoid sparks.
9.
Remove probe from dipstick tube while wiping
with a rag to prevent oil drips.
10. To empty the container, unscrew the pour cap
and pour the oil into a suitable container for
disposal/recycling.
11. For extended storage, flush pump with water
based degreaser solution.
NOTICE: Always recycle used oil in compliance with
federal and local legislation. Handle petroleum prod-
ucts in an environmentally responsible manner.
*Geolast is a registered trademark of Monsanto.
**Viton is a registered trademark of du Pont de Nemours & Co.
Model
Number
17860-2012
Oil Changer System
Polypropylene
*Geolast®, oil resistant
**Viton®, oil resistant
12Vwith integral power switch
Plastic with 3.5 Gal. (13.2L)
(maximum) capacitytank
6ft. (1.8m) with alligator clips
8ft. (2.4m), oil & heat resistant
7 lb (3.17 Kg)
Voltage
12
Model 17860-2012
Amp Draw
2A
Flat Tank
Fuse Size
5A