MAINTENANCE
IF YOUR OXYGEN BAR IS IN NEED OF SERVICE, SEND THE UNIT TO ZADRO
PRODUCTS FOR EXAMINATION OR REPAIR.
CLEANING THE HEADSET AND TUBES
1.
Water condensation may form in the air flow tube and essential oil reservoir if using
the oxygen bar in high humidity locations. Clean both pieces before storing the unit for
long periods of time.
2.
Rinse the airflow tube and essential oil reservoir with warm water and allow to air dry
before storage or re-attaching the parts to the unit.

CLEANING THE UNIT

1.
Unplug the unit from electrical outlet. Wipe the unit with a soft clean cloth that's
slightly damp with water, then wipe dry with a dry cloth. Do not use paper towels
(fibers can get caught in the unit's vents).
2.
Do not use washing detergents, benzene, thinner or alcohol.
CLEANING THE WATER RESERVOIR
1.
Open the water tank panel and slide out the water cup from the unit.
2.
Rinse the cup with warm water and dry with a cloth before attaching back to the unit.
Do not use washing detergents, benzene, thinner or alcohol.
CLEANING THE ESSENTIAL OIL RESERVOIR
1.
Twist to unlock the essential oil reservoir.
2.
Rinse each piece of the reservoir with warm water. Do not use washing detergents,
benzene, thinner or alcohol.

REPLACING FUSES

NOTE: FUSES DEGRADE WITH TIME AND WILL FAIL AFTER REPEATED USE. A BLOWN
FUSE DOES NOT MEAN THAT THERE IS SOMETHING WRONG WITH THE UNIT. IF A FUSE IS
REPEATEDLY FAILING, SEND THE UNIT TO ZADRO PRODUCTS FOR INSPECTION OR SERVICE.
FIGURE 1
1.
Before opening the fuse door, turn off the power and unplug the unit.
2.
Locate the fuse door on the back of the unit between the ON/OFF switch and the
electrical plug port. With the power off and the unit unplugged, use a small blunt item
such as tweezers or a small screw driver to remove the fuse door assembly (see Figure
1). The fuse door assembly can be removed by pulling the small notch on the right side
of the door outward (see Figure 2). The fuse door assembly will come completely out
of the unit (see Figure 3). Note: To avoid damage, pull slowly so that the fuse door does
not fly out of the fuse slot.
3.
With the fuse door assembly removed, simply unclip the fuse.
4.
Insert a new 5A - 250V "Little Fuse" into the fuse door assembly clip.
5.
Re-insert the fuse door assembly into the unit until you feel a click and the door is flush
with the unit surface.
TROUBLESHOOTING
1.
THE UNIT DOESN'T TURN ON.
• Check that the power cord is securely plugged into a nearby electrical outlet.
• Check that the power cord is undamaged.
• Check that your wall outlet is live and undamaged.
• Check if the fuse in the back of the unit is black or the wire is broken. If so, replace the
fuse with a standard 5 amp fuse from a local hardware supply store.