USAGE AREAS
• Stairway space areas (Houses, offices, etc.)
CAUTIONS FOR USAGE & MOUNTING
• Mounting of the product must be done by an electrician.
• Turn off the network before mounting.
• Use 16A fuse to the supply input.
• Mount the device to smooth surface.
SPECIFICATIONS
Operating voltage
Contact current
Time setting
Protection Class
Max Watt
* Short-circuit protected
* Suitable for illuminated light switch
MOUNTING SCHEME
(L) Line, (LS) Lamp, (N) Neutral, (B) Button,
Neutral
Do the mounting by following instructions below.
N
LS
L
B
2 min. 3 min. 4 min.
1 min.
5 min.
-
2 sec.
+
Time setting
TROUBLESHOOTING
MALFUNCTION
After supply voltage the system,
if the fuse turns off.
The device starts to operate itself
The device does not operate
The device turns off itself
TS EN
60669-2-3
TIME-DELAY SWITCH
(Rail mounting)
230-240V~ 50/60 Hz
µ
16A
Min. 2 ± 1sn. - Max. 5 ± 1 dk.
IP20
CLASS 2
3200W
1200W
Automatic-continuous switch
When the switch turns to "Automatic" position, the device will
operate by every push.
Automatic-continuous switch
When the switch turns to "Countinuous" position, the device will
operate continuously. There is no need to puss button.
When the arrow turns to (+) direction, operation period/time will
increase.
When the arrow turns to (-) direction, operation period/time will
decrease.
Bad wiring
Bad wiring
Bad wiring
Factory adjustment
is at minimum time
info@na-de.com.tr
03006
CAUSE
•
www.na-de.com.tr
SOLUTION
Check the wiring
Check the wiring
Check the wiring
Change the time period
KK-03006_150505_EN_00