Descargar Imprimir esta página

NA-DE 03009 Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

USAGE AREAS
• Stairway space areas (Houses, offices, etc.)
CAUTIONS FOR USAGE & MOUNTING
• Mounting of the product must be done by an electrician.
• Turn off the network before mounting.
• Use 10A fuse to the supply input.
• Mount the device to smooth surface.
SPECIFICATIONS
Operating voltage
Contact current
Time setting
Protection Class
Max Watt
* Short-circuit protected
* Suitable for illuminated light switch
MOUNTING SCHEME
(L) Line, (LS) Lamp, (N) Neutral, (B) Button,
Neutral
Do the mounting by following instructions below.
N
LS
L
B
2 min. 3 min. 4 min.
1 min.
5 min.
2 sec.
-
+
Time setting
TROUBLESHOOTING
MALFUNCTION
After supply voltage the system,
if the fuse turns off.
The device starts to operate itself
The device does not operate
The device turns off itself
TS EN
60669-2-3
03009
TIME-DELAY SWITCH
(Rail mounting)
230-240V~ 50/60 Hz
µ
10A
Min. 2sec ± 1sec. - Max. 5min. ± 1min.
IP20
CLASS II
2000W
800W
Automatic-continuous switch
When the switch turns to "Automatic" position, the device will
operate by every push.
Automatic-continuous switch
When the switch turns to "Countinuous" position, the device will
operate continuously. There is no need to puss button.
When the arrow turns to (+) direction, operation period/time will
increase.
When the arrow turns to (-) direction, operation period/time will
decrease.
Bad wiring
Bad wiring
Bad wiring
Factory adjustment
is at minimum time
For further information, please call :
info@na-de.com.tr
CAUSE
0 800 261 78 05
www.na-de.com.tr
SOLUTION
Check the wiring
Check the wiring
Check the wiring
Change the time period
KK-03009_150505_TR/EN_00

Publicidad

loading