Safety guideline
BEWARE:
The device is not intended for use by persons
(including children) with impaired or limited
physical, sensory and mental abilities or lack of
experience and/or real knowledge, unless they
are supervised by a person responsible for their
safety or you follow the instructions made by this
person how to use the device correctly.
Children should be supervised to make sure that
they do not play with the device.
ATTENTION:
• Run a visual inspection of the device before
every use. Do not use the device if the safety
appliances are damaged or worn out. Never
override safety regulations.
• Use the device exclusively according to the
intended purpose stated in the instructions for
use.
• You are responsible for the safety of the working
environment.
• If the cable or the plug is damaged due to
external influences the cable must not be
repaired! It has to be replaced with a new
one. This work can be carried out only by an
electrician.
• The voltage indicated on the type plate of the
device of 230 Volt alternating voltage has to
correspond to the existent mains voltage.
• Never lift, carry or fixate the device by using the
power cable.
• Make sure that the electrical plug connection
is placed in a flood-proof area and is protected
from moisture.
• Disconnect the mains plug before the
maintenance work.
• Avoid exposing the diesel pump to direct water
jets or rain.
www.DeubaXXL.de
• The user is responsible for the compliance
with location specific safety and installing
regulations. (Ask an electrician).
• Consequential damage arising from flooded
rooms caused by dysfunctions of the appliance
must be avoided by means of the appropriate
measures. (installing an alarm system, reserve
pump).
• In case of malfunction the repair work can be
carried out only by a qualified electrician.
• The appliance must not run dry or with
a
completely
closed
intake
port.
The
manufacturer's guarantee is no longer valid if
the damage is caused by dry running.
WARNING:
Read carefully all the safety guidelines and the
instructions.
Non-compliance with the safety rules and
regulations can lead to an electric shock, fire and/
or serious injury. Keep the instructions and the
safety guidelines in a safe place in case you need
them in the future.
Stability
The max. temperature of the conveyed liquid
should not exceed +35°C in permanent operation.
The pump must not convey aggressive fluids
(acids, alkali etc.) or fluids with abrasive
substance (sand). It must NOT pump water or
easy flammable liquids (petrol).
Field of application
For conveying and transferring fuel oil (heating
oil) or diesel fuel.
Technical Data:
Model
DBDP003
Power consumption
160 W
Voltage/Frequency
12 V
Max. flow rate
40 l/min
Max. delivery height
10 m
Connection
1" IG
Electrical connection
• Use a suitable power supply. This means a this
a 12 V car battery.
• Do NOT install on a 230 V power supply at 50Hz.
• The pump is turned on and off by means of a
built-in ON-/OFF switch. The indicator lamp
inside the switch lights up if the engine is
started.
• The engine is protected against overloading
or blocking by means of a built-in motor
protection. In case of overheating the pump is
turned off automatically due to the overheat
protection and after its cooling, the pump is
automatically started.
Suction pipeline
• Connect a suction hose (plastic hose minimum
3/4"with spiral reinforcement) directly or with
a threaded fitting to the suction connection
(intake connection) of the pump (1" Inside
thread) of the pump.
• The suction hose that is used should have a
suction valve. In case the suction valve cannot
be used, a check valve should be installed in the
suction line.
• Position the suction line on a rising gradient
from the removal point towards the pump.
Avoid laying the suction line over the pump
height, air bubbles in the suction line delay and
prevent the suction process.
• Suction and pressure line must be placed in
such a way so that they exert no mechanical
pressure on the pump.
• The suction valve should lie deeply enough in
the medium to be pumped. This way the drop
in the fluid level prevents the pump from dry
running.
• A leaking suction line prevents the suction of
the pumped medium by sucking in air.
• Avoid sucking foreign particles (sand etc.).
Commissioning
• Set up the pump on a fixed, flat place, where
the temperature does not exceed 40°C. The
pump has to be placed in a horizontal position,
so that the bearings can function properly,
screw the pump tight to its bottom part.
• Bring the suction line ready for operation. The
suction hose should not be narrower than the
suction connection. If the suction lift exceeds 4
m, use a suction line with a larger diameter.
• Proceed with the electrical connection.
Cleaning
The heating oil pump must be cleaned only by
using mild cleaning agents as well as a damp
cloth and soapy water. Damage caused by
inappropriate cleaning agents is not covered by
warranty.
Maintenance
• The pump is maintenance free. For a long
operation life we recommend regular checking
and servicing.
Attention!
Before every maintenance work the pump
must be switched off, pull out the plug from the
power socket.
• After long non-operation periods check if a
proper turning of the rotor takes place.
www.DeubaXXL.de