Main components
1. UP button
2. Programming button
3. Sun adjustment trimmer
4. Wind adjustment trimmer
5. Indicator LEDs
6. Panel power supply terminal block
7. Anemometer
8. Sun sensor
9. Single working frequency
⚠ Before intervening on the device,
disconnect the line voltage.
Description of button functions
Programming: for memorising the weather
station.
TRIMMER ADJUSTMENTS
Trimmer ③ = adjusting the sensitivity of the
sun threshold level: 15 klux (+ sensitive) / 60
klux (- sensitive).
Trimmer ④ = adjusting the sensitivity of the
wind threshold level: 5 km/h (+ sensitive) / 40
km/h (- sensitive).
INDICATOR LEDS
• transmission (TX): fl ashing red;
• sun alarm: fl ashing red, 6" on and 6" off ;
• wind alarm: steady red
INSTALLATION
⚠ Installation must be carried out by qualifi ed
and experienced personnel in compliance
with applicable regulations.
Preliminary checks
Check that the point where the weather station
is secured is in an area protected from shocks,
but still exposed to air circulation and sunlight,
depending on the model chosen. Secure it on
fl at, solid surfaces using suitable equipment
(screws, anchors etc.).
Prepare suitable piping and ducts for routing
the electrical cables, ensuring protection
against mechanical damage.
Equipment and materials
Securing and putting into operation
Stages , , , , , and .
ANEMOMETER PRESENT
FUNCTION
If the wind sensor does not move within 120
hours, the weather station sends a closing
signal to the awning and will repeat this every
15' until anemometer activity is detected.
ELECTRICAL CONNECTIONS
ⓐ
blue (common);
ⓑ
brown (phase);
yellow/green (earth);
ⓒ
blue (power);
ⓓ
ⓔ
brown (power).
ACTIVATING THE STRAUSS KLT
P2 P2 of the TX which is already memorised
, P2 of the new TX
.
For all other memorisations/features, see
the instructions for the motor or of the
combined control unit.
WEATHER STATION COMMANDS
The STRAUSS weather station associates
diff erent priorities to the alarms:
the wind alarm has absolute priority over the
sun alarm, disabling it.
Wind alarm
When the wind speed exceeds the set threshold
value for 2", the weather station enters wind
alarm mode, and a red LED lights up and
stays on.
The weather station closes the awning, keeping
it closed for the alarm time plus an extra 15'
for safety reasons.
Sun alarm
STRAUSS KLT SW: when the threshold level is
exceeded for 2', the weather station commands
the opening of the awning.
The red LED on the panel fl ashes when the set
threshold is exceeded.
When the level of light drops below the
threshold for at least 15' , the weather station
commands the closing of the awning and exits
alarm mode.
If the level of light drops rapidly, in 3' , under
the value of 15 klux, the weather station
commands the closing of the awning and exits
alarm mode.
Declaration - Came CancelliAutomatici
S.p.A. declares that this device
complies with the essential requirements
and other relevant provisions established
in Directives 2006/95/EC, 2014/30/UE
and 1999/05/EC.
Reference code to request an original
copy: DDC RA H008.
Decommissioning
and
disposal
Before proceeding, it is always advisable
to check specifi c regulations in force in
the place of disposal.
Other
components
(circuit
boards,
transmitter
batteries
on
the
other hand, may contain
pollutants. They should therefore be
removed
and
handed
over
companies
authorised
to
recover
and recycle them.
DISPOSE OF PROPERLY!
The data and information provided in
this manual are subject to change at
any time without prior notice.
119T70549
119T70549 - ver. 2 2 - 01/2013
-
etc.),