Technical Features - Belshaw DOMIX 35 El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

1.
Ball-taps with OR gasket.
2.
OR gasket-type unions for an easier installation.
3.
Double stainless steel net filters for water impurities.
4.
No-return valves .
5.
Regulation knob for setting temperature, with reference scale.
6.
Key STOP/C for manual stop or eventual clearing of memory.
+
-
7.
Keys
and
8.
Key START for starting or restarting water delivery.
9.
Supply plug, with fuse and spare, and remote pump control plug, with fuse and spare.
10. 2,5m delivery hose with stainless steel terminals.
11. Series of function control lights.
12. Digital display of electronic internal thermometer, showing °C with tenths or °F.
13. Digital display for selected, yet to be delivered (during batching), or already discharged
(after pressing STOP) litres (or pounds).
Software
Water connections
Max. inlet water temperature
Temperature setting range
Temperature precision
Max. inlet water pressure
Min. inlet water pressure
Max. ratio between the two inlet pressures
Max. dosage quantity
Dosing precision
Water delivery at 1bar and 20°C
Water delivery at 5bar and 20°C
Voltage (see equipment rating plate)
Frequency
Power absorption
Supply fuse
Pump remote control fuse
for setting the quantity.

TECHNICAL FEATURES

DESCRIPTION
(see figure 1)
DOX35.02a
1/2"
65°C
2°C – 60°C
1°C
5bar
1bar
1 : 5
999,9l
1%
18l/min.
40l/min.
230 or 110V
50/60Hz
25VA
250V 250mA delayed
250V 6,3mA delayed
2600102 / 11.XII.2001
1