Safety
Important Safety
Instructions
SAVE THESE INSTRUCTIONS - This manual
contains important instructions that should be
followed during installation, operation, and
maintenance of the product.
This is the safety alert symbol. When you
see this symbol on your pump or in this manual,
look for one of the following signal words and
be alert to the potential for personal injury!
indicates a hazard which, if not
avoided, will result in death or serious injury.
indicates a hazard which, if not
avoided, could result in death or serious injury.
indicates a hazard which, if not
avoided, could result in minor or moderate
injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions
in this manual and on pump.
Keep safety labels in good condition. Replace
missing or damaged safety labels.
California Proposition 65 Warning
This product contains chemicals
known to the State of California to cause cancer
or birth defects or other reproductive harm.
For parts or assistance, call Simer Customer Service at
1. Read this manual carefully. Failure to follow
these Instructions could cause serious bodily
injury and/or property damage.
2. Consult installer or licensed plumber for correct
relief valve. Install system according to local
codes.
3. Always test water from well for purity before
using. Check local health department for testing
procedure.
4. Before installing or servicing tank, BE SURE
pump electric power source is disconnected.
Release all water pressure before working on
tank or system. Release air pressure before
removing cover flange.
5. Install relief valve in pump supply line to tank,
as close to tank as possible.
6. BE SURE pump electrical circuit is properly
grounded.
7. Remove bleeder orifices, air volume controls or
other air charging devices in existing system.
8. DO NOT USE tank as a surge suppressor.
Risk of explosion. Pump body may
explode if used as a booster pump unless relief
valve capable of passing full pump flow at
75 PSI is installed. Do not ground to a gas
supply line. To prevent possible serious or fatal
injury and/or damage to equipment, system
pressure must be less than 100 pounds per
square inch (PSI) (689kPa) under any
circumstances. Failure to follow instruction can
result in tank blowup. If system discharge
pressure can exceed 100 PSI (689kPa), install a
relief valve capable of passing the full pump
volume at 100 PSI (689kPa).
Risk of freezing. Do not allow
pump, tank, or piping system to freeze. Freezing
can severely damage equipment and may lead
to tank explosion and serious injury. Allowing
tank to freeze voids tank warranty.
1-800-468-7867
2