INSTRUCTIONS FOR USING THE PRODUCT
The cooler box must be well-ventilated, particularly at the back. Always ensure that there
is 100 mm free space around the cooler box.
Do not allow the inside walls to become too thickly frosted up, as this may prevent cooling.
Defrost the cooler box by switching it off so that the ice would melt and become water.
The lower the outside temperature, the less energy the cooler box will use. To optimise the
efficiency of the cooler box, always ensure that it is placed in a cool area and away from
the sun.
It is recommended that the cooler box be placed on a flat surface. It will, however, function
at a listing angle of 30°.
TECHNICAL
Power supply: 12 V and 24 V direct current
Battery protection: Select position L, M or H by using the switch (located next to the power
switch) to set the required level of battery protection. The table below indicates the
voltage when the compressor stops functioning (cut-out) and when the compressor
restarts again (cut-in).
Battery
protection
L
M
H
Cable length specifications
The continuous supply power cables must have a section that is adequate for their length
(measured from the battery to the cooler box) as set out in the table below:
Cable thickness
[mm²]
2,5
4
6
10
12V cut-out
12V cut-in
9,6V
10,9V
10,1V
11,4V
11,1V
12,4V
12 V maximum cable length
[m]
2,5
4
6
10
24V cut-out
24V cut-in
21,3V
22,7V
22,3V
23,7V
24,3V
25,7V
24 V maximum cable length
[m]
5
8
12
20
17