COB
PAR 200
FIXTURE CLEANING
The cleaning of internal and external optical lenses must be carried out periodically to
optimize light ouput. Cleaning frequency depends on the environment in which the
xture operates: damp, smoky or particularly dirty sorrounding can cause greater
accumulation of dirt on the unit´s optics.
- Clean witch soft cloth using normal glass cleaning uid
- Always dry the parts carefully
- Clean the external optics at least every 20 days. Clean the internal optics at
least every 30/60 days
DMX MODES
4CH MODE
CH
VALUE
1
0
1-255
2
0
1-255
3
0
1-255
4
0
1-255
8CH MODE
CH
VALUE
1
0
2
0
1-255
3
0
1-255
4
0
1-255
5
0
1-255
6
1-255
7
1-255
8
0-50
51-100
101-150
151-200
201-250
251-255
ENGLISH
FUNCTION
Red o
Gradual change, from dark to bright
Green o
Gradual change, from dark to bright
Blue o
Gradual change, from dark to bright
White o
Gradual change, from dark to bright
FUNCTION
Master Dimmer
Red o
Gradual change, from dark to bright
Green o
Gradual change, from dark to bright
Blue o
Gradual change, from dark to bright
White o
Gradual change, from dark to bright
Strobe from slow to fast
Speed from Slow to fast
CH1-CH5 open
Program color selection
Program gradual change
Program pulse change
Program Jump change