Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Electronic Metered High Volume Control Valve
Description
CAUTION
Do not operate this metered valve with an antifreeze
and water mixture. Meter will not register properly.
The metered control valve models included in the 3570
series are designed to meter quantities of a variety of fluids.
These valve assemblies dispense engine oils, diesel oils, and
hydraulic oils. Refer to Service Guide SER 3579 for meter
description and operation.
WARNING
Release all pressure within the system prior to
performing any overhaul procedure.
• Disconnect the air supply line from the pump
motor.
• Into an appropriate container, operate the control
valve to discharge remaining pressure within the
system.
Never point a control valve at any portion of your body
or another person. Accidental discharge of pressure
and/or material can result in personal injury.
Read each step of the instructions carefully. Make sure
a proper understanding is achieved before proceeding.
Assembly
Apply thread Sealant to the male threads on the extension (1
or 2).
NOTE: Do not apply thread sealant to the first two
(2) threads. Contamination can occur.
Install the Extension into the Electronic Meter Assembly (6).
Tighten securely.
Prime and Test
NOTE: Perform the following procedures at an air
pressure that allows the pump to begin to cycle.
Regulate the amount of air to the pump with a pres-
sure regulator.
Should valve leakage occur at anytime, refer to the
Troubleshooting Chart.
Model
3570-B
3571-B
Note: All meters are programable for Pints, Quarts, Gallons and Liters
This document contains confidential information that is the property of Alemite, LLC
670954
and is not to be copied, used, or disclosed to others without express written permission.
1-800-548-1191 - http://www.partdeal.com - info@partdeal.com
Service Guide
Fluid Metered
Extension
Oil
Rigid
Oil
Flexible
Alemite, LLC
167 Roweland Drive, Johnson City, Tennessee 37601
www.alemite.com
©
Copyright
Figure 1 Electronic Metered Control Valve Model 3570-B & 3571-B
Fluid Inlet (Swivel)
Maximum Operating Pressure
1. Point the control valve into an appropriate collection
container.
2. Allow the pump to deliver fluid to the control valve.
• The control valve should show no leakage nor dispense the
fluid.
3. Cycle the control valve Lever Assembly several times.
• Fluid should flow once air is eliminated from the control
valve (and system).
If the control valve does not dispense the fluid, refer to the
Troubleshooting Chart.
With the Lever in the released position, no fluid should
appear at the Nozzle. If product does appear, refer to the
Troubleshooting Chart.
Should the electronic meter not function properly, refer to
Service Guide SER 3579 for details.
The non-drip nozzle opens automatically when fluid is
dispensed.
After use, the nozzle should be manually pushed closed to
prevent oil drip.
Nozzle Type
Non-Drip Manual
Non-Drip Manual
2008 by Alemite, LLC
3570-B
3571-B
3/4" NPTF (f)
1000 psi (70 bar)
Units of Measure
(preprogrammed)
Gallon
Gallon
SER 3570
Revision (3-08)

Publicidad

loading

Resumen de contenidos para Alemite 3570-B

  • Página 1 © Copyright 2008 by Alemite, LLC SER 3570 This document contains confidential information that is the property of Alemite, LLC Revision (3-08) 670954 and is not to be copied, used, or disclosed to others without express written permission. 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 2 Model Item Part No. Description Notes 393792-1 Extension, Rigid 393792-2 Extension, Flexible 393792-3 Swivel Assembly Includes Strainer (5) 393792-4 Valve Seal Kit 393792-5 Strainer See SER 3579 393792-6 Meter Assembly, Electronic Revision (3-08) Alemite, LLC 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 3: Troubleshooting Chart

    2. Thread sealant missing or inadequate 2. Apply thread sealant* to male pipe threads * Do not apply thread sealant to the first two (2) threads. Contamination can occur. Changes Since Last Printing Alemite, LLC Revision (3-08) 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 4: Guía De Servicio

    Nota: Todas losmedidores son programables para medir en pintas, cuartos, galónes y litros © Copyright 2008 by Alemite, LLC Este documento contiene información confidencial que es propiedad de Alemite, LLC SER 3570 y no se debe copiar, usar o revelar a terceros sin una expresa autorización por escrito. Revisión (3-08) 670954 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 5 Descripción Cant Notas parte 393792-1 Extensión Rígida 393792-2 Extensión Flexible 393792-3 Ensemblaje giratorio Incluye el tamiz 393792-4 Kit para la Válvula de Control 393792-5 Tamiz 393792-6 Medidor Electrónico (basico) Revise 3579 Revisión (3-08) Alemite, LLC 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...
  • Página 6 2. Aplique sellante* a las roscas de tubo macho * No aplique sellante a las dos (2) primeras roscas. Puede provocar contaminación. Cambria desde la impresi n pasada ó Alemite, LLC Revisión (3-08) 1-800-548-1191 - http://www.partdeal.com - info@partdeal.com...