Important Remarks - ACM MINI-RX1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Description
The MINI-RX1 module allows to control a single phase
asynchronous motor for the automation of awnings and rolling
shutters.
The small size of the container allows the module to be easily
inserted inside the switches.
Power supply with extended range: 85 ÷ 260 Vac - 50/60 Hz
Very low power consumption in stand-by
434.15 MHz radio receiver with integrated antenna
Compatible with TX-PLUS and TX-FIT series transmitters
Stores up to 30 radio channels
Two wired inputs: up and down
Output to control a single phase asynchronous motor
Integrated button for programming operations
Wireless programming via a remote control provided with
memory
Wireless management of VIBE series sensors.
Specifications
Power supply ______________________ 85 ÷ 260 Vac - 50/60 Hz
Consumption in stand-by ____________ 0,25 W
Motor maximum power _____________ 500 W
Operating temperature ______________ -20 ÷ +60 °C
Maximum operating time____________ 120 s
Protection _________________________ IP10

IMPORTANT REMARKS

Attention: for people safety it is important to follow carefully
the instructions. Keep the instructions.
Important safety instructions for the installation.
Attention: a wrong installation can cause serious accidents.
Follow carefully the installation instructions .
This device can be installed only from qualified persons.
The control buttons and the connection cables shall have
insulation properties suitable for electrical installations with
operating voltage of not less than 300Vac
In order to protect the device, the installer must provide for
a magnetotermical differential switch (separation among the
contacts: at least 3 mm), ensuring the omnipolar sectioning
from the power supply.
The device must be installed only inside a junction box or wall
box.
The device container does not provide any protection
against water. Thus, it should be installed only in protected
environments.
WIRING
COM P1
M
p
Motor up
q
Motor down
COM
Motor common
P1
Entry of button P1 (up control)
P2
Entry of button P2 (down control)
N
Power supply neutral
L
Power supply phase
NOTE: The motor direction (up/down) depends on the
position of the motor and wiring.
- 4 -
P2
N
L