Description
The MINI-RX1 module allows to control a single phase
asynchronous motor for the automation of awnings and rolling
shutters.
The small size of the container allows the module to be easily
inserted inside the switches.
•
Power supply with extended range: 85 ÷ 260 Vac - 50/60 Hz
•
Very low power consumption in stand-by
•
434.15 MHz radio receiver with integrated antenna
•
Compatible with TX-PLUS and TX-FIT series transmitters
•
Stores up to 30 radio channels
•
Two wired inputs: up and down
•
Output to control a single phase asynchronous motor
•
Integrated button for programming operations
•
Wireless programming via a remote control provided with
memory
•
Wireless management of VIBE series sensors.
Specifications
Power supply ______________________ 85 ÷ 260 Vac - 50/60 Hz
Consumption in stand-by ____________ 0,25 W
Motor maximum power _____________ 500 W
Operating temperature ______________ -20 ÷ +60 °C
Maximum operating time____________ 120 s
Protection _________________________ IP10
IMPORTANT REMARKS
•
Attention: for people safety it is important to follow carefully
the instructions. Keep the instructions.
•
Important safety instructions for the installation.
Attention: a wrong installation can cause serious accidents.
Follow carefully the installation instructions .
•
This device can be installed only from qualified persons.
•
The control buttons and the connection cables shall have
insulation properties suitable for electrical installations with
operating voltage of not less than 300Vac
•
In order to protect the device, the installer must provide for
a magnetotermical differential switch (separation among the
contacts: at least 3 mm), ensuring the omnipolar sectioning
from the power supply.
•
The device must be installed only inside a junction box or wall
box.
•
The device container does not provide any protection
against water. Thus, it should be installed only in protected
environments.
WIRING
COM P1
M
p
Motor up
q
Motor down
COM
Motor common
P1
Entry of button P1 (up control)
P2
Entry of button P2 (down control)
N
Power supply neutral
L
Power supply phase
NOTE: The motor direction (up/down) depends on the
position of the motor and wiring.
- 4 -
P2
N
L