Descargar Imprimir esta página

Adler EVOV2M1 Guia De Inicio Rapido página 2

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EVOV2M1 - PCB 20881 - ERRORS
DISPLAY
DESCRIPTION
Boi l er tempera ture probe
E1
s hort ci rcui t.
Ta nk tempera ture probe
E2
s hort ci rcui t.
Wa ter fi l l not compl eted
E3
duri ng ma x ti me a va i l a bl e
(defa ul t 15 mi n).
Boi l er ma x tempera ture s et
E4
poi nt rea ched (defa ul t
100°C / 212°F).
Ta nk ma x temperature s et
E5
poi nt rea ched (defa ul t 85°C
/ 185°F).
Wa ter dra i n not compl eted
duri ng ma x ti me a va i l a bl e
(defa ul t 2 mi n).
Boi l er hea ti ng ma x ti me
E7
rea ched (defa ul t 30 mi n).
Ta nk hea ti ng ma x ti me
E8
rea ched (defa ul t 55 mi n).
Boi l er tempera ture probe
E9
not connected.
Ta nk tempera ture probe
E10
not connected.
Ta nk s a fety thermos ta t
E11
a cti va ted.
Boi l er s a fety thermos ta t
E12
a cti va ted.
Memory pa ra meters error
E00
or pcb boa rd fa ul ty.
USER
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE ASSISTANCE.
Press button "C" for 1 s ec a nd res ta rt fi l l i ng pha s e.
Verify correct wa ter s uppl y
connecti on, open a nd free of obs tructi ons .
Verify s ol enoi d va l ve i nterna l fi l ter i s free of
obs tructi ons a nd depos i t.
Verify a degua te wa ter s uppl y pres s ure
(pa r.1D – Techni ca l Da ta).
Verify correct cl os ed door a nd pos i ti on of the overfl ow
devi ce (wa ter l evel pi pe).
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Verify the overfl ow devi ce (wa ter l evel pi pe) i s
removed a nd free of obs tructi ons on the drai n l i ne.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
Bl ocki ng a l a rm. CALL TECHNICAL SERVICE FOR
ASSISTANCE.
TECHNICIAN / INSTALLER
Replace the probe.
Replace the probe.
Verify correct pres s ure s wi tch opera ti on.
Verify correct s ol enoi d va l ve opera ti on.
Verify the ma chi ne worki ng correctl y. If the probl em
pers i s ts repl a ce the pcb boa rd.
Verify the ma chi ne worki ng correctl y. If the probl em
pers i s ts repl a ce the pcb boa rd.
Verify the overfl ow devi ce (wa ter l evel pi pe) i s removed
a nd free of obs tructi ons on the dra i n l i ne.
Verify dra i n el ectri ca l wi res a re connected correctl y to
the pcb board.
Verify connecti on of the hea ter el ement wi res to the pcb
boa rd.
Verify correct hea ter el ement opera ti on a nd free of
l i mes tone.
Verify connecti on of the hea ter el ement wi res to the pcb
boa rd.
Verify correct hea ter el ement opera ti on a nd free of
l i mes tone.
Verify connecti on of the hea ter el ement wi res to the pcb
boa rd.
Verify pos i ti on of the probe i ns i de the boi l er a nd free of
l i mes tone.
Verify connecti on of the hea ter el ement wi res to the pcb
boa rd.
Verify pos i ti on of the ta nk probe a nd free of l i mes tone.
Remove the front pa nel a nd res et the s a fety thermos ta t
by pres s i ng the bl a ck button.
Verify the ma chi ne i s worki ng correctl y.
Remove the front pa nel a nd res et the s a fety thermos ta t
by pres s i ng the red button.
Verify the ma chi ne i s worki ng correctl y.
Replace the pcb boa rd.
2 / 10