Descargar Imprimir esta página

Price Pfister 16 Serie Manual Del Usuario página 2

Ocultar thumbs Ver también para 16 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Thank you for purchasing this Price Pfister product. All Price Pfister products are carefully engineered, and factory tested to
provide long trouble-free use under normal conditions. This product is easy to install using basic tools and our easy to follow
illustrated instructions. If you have any questions regarding this product, call 1-800-Pfaucet (1-800-732-8238).
1 BEFORE PROCEEDING
WARNING: Read all the instructions completely before proceeding. Price Pfister
recommends calling a professional if you are uncertain about installing this product!
This product should be installed in accordance with all local and state plumbing and
building codes.
WARNING: This product has been designed for use with the Price Pfister 15-IWD
series diverter valve. It will not work with any other product. Please review the 15-IWD
series diverter valve installation instructions before installing this product.
2 SHUT OFF WATER SUPPLY
Locate water supply inlets and shut off the water supply valves. These are usually found
near the water meter. If you are replacing an existing unit, remove the old unit and clean
the mounting surface thoroughly.
3
3 TOOLS RECOMMENDED
• PTFE plumber's tape or thread sealant
• Pliers
• Adjustable wrench
Your installation will require a pipe nipple for the spout installation as well as other
additional tools.
4
G
F
E
D
4 CHECKING THE CONTENTS OF THE BOX
Upon opening the box, check to ensure that all of the following items are
included.
A Handle
B Trim Flange
D Retainer Sleeve
E Extension Stem
G Set Screw
If any of these items are missing, please contact Price Pfister Consumer Service
at 1-800-Pfaucet (1-800-732-8238).
ENGLISH
• Philips head screwdriver
• Flashlight
• Cloth
A
C
B
C Washer
F Hex Wrench
5
5F
2.00" Dia.
5E
5C
TO
PRIMARY
OUTLET
5 VALVE LOCATION
Be sure that Diverter Valve Body (5A) is positioned correctly in wall, where the
Supply Valve Shower Outlet is to connected to one of the Diverter Valve Body
Inlets (5B). Be sure that Shower Outlet (5C) and Tub Outlet (5D) connections
are properly connected. Be sure that the other Diverter Valve Outlet (5E) is
plugged.
Center Hole (5F) on wall is 2.00" Dia.
6
6A
6 COVER REMOVAL
Remove Plastic Cover (6A) from Diverter Valve Body (6B).
2
5E
5A
5B
5D
TO
SECONDARY
OUTLET
5B
INLET
6B