INSTALLATION: YOKE MOUNT
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
1. Use expansion bolts (not included) to secure the fixture on mounting surface.
2. Keep enough length on the wires to ensure fixture can be adjusted to desired angle unhindered.
3. Connect wires into wiring terminal; white wire to "neutral" terminal, black wire to "live" terminal, and green wire to
"ground" terminal.
4. Ajust the fixture to desired angle and tighten the screws on the side of fixture to secure.
1
INSTALLATION: KNUCKLE MOUNT
ALWAYS TURN OFF THE POWER SUPPLY FROM MAIN CIRCUIT BREAKER FIRST!
1. Adjust the screw to allow the fixture to be adjusted up or down.
2. Secure service wire or conduit to the wiring compartment cover with 1/2" connector (not provided).
3. Connect white fixture wire to white supply wire, black fixture wire to black supply wire. Service ground should be
attached to green ground screw provided. Ground must be properly attached to avoid the risk of electrical shock.
Use wire nuts, crimp-on lugs, or other approved devices to connect all wires, make sure connections are secure
and that no loose wire strands are sticking out of connectors, Secure wiring compartment cover to fixture. With
black and white connections inside the wiring compartment.
1
EiKO Global, LLC • 23220 W. 84th St, Shawnee, KS 66227 • (P) 1-800-852-2217 • (F) 1-800-492-8975 • eiko.com