Fan/Light Control
RAY2LFSQ, RS2LFSQ
Rated at 120 V~ 60 Hz 1.5 A fan / 300 W light
Important Notes
Please read before installing.
1. CAUTION: Use control with a ceiling paddle fan only. Use only one ceiling paddle
fan per control. To avoid overheating and possible damage to other equipment, do
not use to control receptacles, fluorescent lighting fixtures, or transformer-supplied
appliances.
2. Controls require separate wires in the wallbox for fan and light. Do not use control
with a fan and light that operate with the same switch.
3. Set multi-speed fans to their highest setting before installing control.
4. Do not wire control in a circuit with a GFCI breaker/receptacle.
5. Install in accordance with all national and local electrical codes.
6. When no "grounding means" exist within the wallbox then the NEC
404-9 allows a control without a grounding connection to be installed as a
replacement, as long as a plastic, noncombustible wallplate is used. For this type of
installation, cap or remove the green ground wire on the control and use an
appropriate wallplate.
7. For new installations, install a test switch before installing the control.
8. Protect control from dust and dirt when painting or spackling.
9. It is normal for the control to feel warm to the touch during operation.
10. Clean control with a soft damp cloth only. Do not use any chemical cleaners.
Multigang Installations
When installing more than one control in the same wallbox, it may be necessary to
remove all inner side sections prior to wiring (see diagram). If pre-installed, remove the
wallplate and wallplate adapter from control. Using pliers, bend side section up and
down until it breaks off. Repeat for each side section to be removed. Note: No derating
required if ganged.
Each Control Has Inside
Sections Removed
This product may be covered by one or more of the following U.S. patents: 4,835,343; 4,835,816; 5,191,971; 5,262,678;
5,359,231; 5,637,930; DES 342,234; and corresponding foreign patents. NEC is a registered trademark of the National Fire
Protection Association, Quincy, Massachusetts.
Installation
1 1
Turning OFF Power.
• Turn power OFF at circuit breaker (or remove fuse).
2 2
Removing Wallplate and Switch.
• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Caution: Verify
power is OFF to
switch before
proceeding.
3 3
Verify Application.
• This control mounts in a single-gang wallbox and independently controls a
ceiling paddle fan and a light with each slider. Independent wire must be
provided for the fan and light in addition to the feed wire (Live).
Break-off
fin
Tag
MARK or TAG the wire that is connected to the feed side of the switch (the side with
the break-off fin.
Hubbell Incorporated (Delaware)
185 Plains Road
Milford, CT 06461-2420
(203) 882-4800
English
4 4
Disconnecting Switch Wires.
Important Note: Your wall switch may have two wires attached to the same screw (see
illustration below for example). Tape these two wires together before disconnecting.
Connect both wires to the control wire in Step 5.
One
continuous
wire to the
screw.
Important Wiring Information
When making wire connections, follow the recommended strip lengths and combinations for the
supplied wire connectors. Note: Wire connectors provided are suitable for copper wire only. For
aluminum wire, consult an electrician.
2005, Article
®
Small:
Strip insulation 3/8" (10 mm) for 14 AWG wire
Strip insulation 1/2" (13 mm) for 16 or 18 AWG wire
Use to join one 14 AWG supply wire with one 16 or
18 AWG control wire.
Large:
Strip insulation 1/2" (13 mm) for 10, 12, or 14 AWG
wire
Strip insulation 5/8" (16 mm) for 16 or 18 AWG wire
Use to join one or two 12 or 14 AWG supply wires
with one 10, 12, 14, 16, or 18 AWG control wire.
5 5
Wiring the Control.
• For installations involving more than one control in a wallbox, refer to the
section on Multigang Installations before beginning.
Note: Wire location will vary by product. Reference wires by color, not
location.
Do Not Remove
Outside Sections
Yellow Tag
Red
Middle Control Has Two
Side Sections Removed
Green
Black
Tag
Black
120 V~
Green
60 Hz
Ground
*Cap off Red wire if no light is used.
6 6
Mounting Control to Wallbox.
• Form wires carefully into the wallbox, mount and align control.
• Install wallplate.
Start screws.
7 7
Turning ON Power.
• Turn power ON at circuit breaker (or replace fuse).
To Light
To Fan
Feed (Live)
Screw Terminals:
Turn screws to
loosen.
Twist wire connector
tight.
Be sure no bare wire
is exposed.
Large
Small
• Connect the green control ground
wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 6.)
• Connect the black control wire to the
tagged wire removed from the switch
(feed wire from the circuit breaker or
fuse box). Remove tag from wire.
• Connect the yellow control wire to
Ground
the wire leading to the fan.
• Connect the red control wire to the
wire leading to the light.
Yellow
Red*
Fan
Light
Align control and
tighten screws.
037-104
Made and printed in the U.S.A.
8/06 P/N 037-104 Rev. A
Commande de ventilateur/luminaire
RAY2LFSQ, RS2LFSQ
Puissance nominale de 120 V~ 60 Hz
1,5 A ventilateur / 300 W luminaire
Remarques importantes
Veuillez lire avant de procéder à l'installation.
1. MISE EN GARDE : Utiliser une commande avec un ventilateur de plafond à pales
seulement. Utiliser seulement un ventilateur de plafond à pales par commande. Pour
éviter la surchauffe et d'éventuels dommages à d'autres équipements, ne pas utiliser
ce dispositif pour commander l'intensité des prises de courant, des luminaires à
tube fluorescent, ou des appareils alimentés par transformateur.
2. Ne pas utiliser les commandes pour un ventilateur et une lumière qui fonctionnent
sur le même interrupteur.
3. Régler les ventilateurs à vitesses multiples sur la plus haute vitesse avant de
procéder à l'installation des commandes.
4. Ne pas raccorder les commandes à un circuit doté d'un disjoncteur/d'une prise
contre masse défectueuse (GFCI).
5. L'installer en respectant tous les codes d'électricité nationaux et locaux.
6. Lorsqu'il n'y a pas de « dispositif de mise à la terre » dans la boîte murale, le NEC
2005, Article 404-9 autorise l'installation en remplacement d'une commande sans
liaison de terre à condition d'utiliser une plaque frontale en plastique non
combustible. Pour ce type d'installation, encapuchonner ou retirer le fil de terre vert
de la commande et utiliser une plaque frontale correspondante.
7. Pour les nouvelles installations, installer un interrupteur d'essai avant de faire la pose
de la commande.
8. Protégez la commande de la poussière et de la saleté lorsque vous peignez ou rebouchez.
9. Il est normal de sentir une chaleur au toucher de la commande intelligent lorsqu'il
fonctionne.
10. Nettoyer la commande avec un chiffon doux et humide seulement. Ne pas
utiliser de nettoyants chimiques.
Installation des commandes multiples
Lors de l'installation de plus d'une commande dans la même boîte murale, il peut être
nécessaire d'enlever toutes les sections latérales intérieures avant de faire le câblage
(voir ci-dessous). Avec des pinces, replier la section latérale de haut en bas jusqu'à ce
qu'elle se sépare. Répéter pour chacune des sections latérales à enlever. Remarque :
Les installations multiples ne requièrent aucun déclassement.
Les sections intérieures de
chaque commande sont
enlevées
Ce produit peut être protégé en vertu de l'un ou de plusieurs des brevets américains suivants : 4,835,343; 5,191,971;
5,207,317; 5,262,678; 5,359,231; 5,637,930; DES 342,234; DES 364,141; et des brevets étrangers correspondants. NEC
est une marque de commerce de National Fire Protection Association, Quincy, Massachusetts.
Installation
1 1
Coupure de l'alimentation électrique.
• Couper l'alimentation au disjoncteur (ou retirer le fusible).
2 2
Dépose de la plaque murale et de l'interrupteur.
• Enlever la plaque murale et les vis de montage de l'interrupteur.
• Retirer délicatement l'interrupteur du mur (ne pas enlever les fils).
Mise en garde :
S'assurer que
l'alimentation
électrique est
coupée avant de
commencer.
3 3
Vérifier l'utilisation.
• Cette commande se monte dans une boîte de sortie unipolaire et
commande indépendamment un ventilateur de plafond à pales et un
luminaire à l'aide de chaque curseur. Des fils indépendants doivent être
prévus pour le ventilateur et pour le luminaire, en plus du fil sous tension.
Section
latérale
enlevée
Étiquette
ÉTIQUETER le fil raccordé au côté sous tension del'interrupteur (le côté avec la section
latérale enlevée)
037-104
Hubbell Incorporated (Delaware)
185 Plains Road
Milford, CT 06461-2420
(203) 882-4800
Français
®
Ne pas retirer
les sections
extérieures
Les deux sections latérales
de la commande mitoyen
sont enlevées
Fil du
luminaire
Fil du
ventilateur
Fil sous
tension
Continué au verso...
Fabriqué et imprimé aux É.-U.
8/06 N/P 037-104 Rev. A