OPERATION CHECKLIST
☑
Check all hose connections.
☑
Use a 12 gauge cord if the cord is shorter than 50 ft (15 m) or a 10 gauge
cord if the cord is longer than 50 ft (15 m).
☑
Provide fresh air intake for the cooler and maintain a minimum clearance
of 3 ft (0.9 m) behind the cooler. Do not operate the cooler in an enclosed
space.
☑
Make sure the the water source does not exceed 120 PSI of water pressure.
☑
Make sure the cooler's reservoir is filled with water before turning on the
pump. The pump automatically shuts off if the water level is too low.
☑
Flush new cooling media.
1.
Fill the cooler with water.
2.
Turn on the pump.
3.
Run the cooler without the fan running for 5 hours.
☑
Make sure the cooling media is evenly saturated.
☑
Dry out the cooling media before shutting down the cooler. Turn off the
pump and leave the fan running for 10 to 15 minutes.
☑
Drain and clean the cooler weekly. Remove the cooling media and rinse with
a garden hose.
☑
To avoid scale and mineral buildup, use water treatment tablets periodically.
One tablet is provided in the cooler's reservoir. Every 3 months, add 1 tablet
to the reservoir after cleaning. Additional tablets are available by calling
877-244-3267.