EN
iSND8 – 8 channel Surround sound
module
Features:
•
8x 10W R.M.S. (max. 60W R.M.S. simultaneous).
•
3 input sources (A, B and C) + 1 input source per
output;
•
line out for (A, B and C).
•
MdiBus interface;
•
Control panel on DIN rail or fastening by non-
standard hole
pattern.
Applications:
•
Surround sound, alarm, video door phone, doorbell,
audible warnings and panic alarms;
Specifications:
Power supply voltage: 15VDC;
Consumption: 6A @ 15VDC;
Storage Temperature: -10ºC to 60ºC;
Operating Temperature: 10ºC to 50ºC;
Maximum humidity: 80% non-condensing;
Speaker Impedance: 4-32Ohm;
Output power per channel: 10W R.M.S.@8Ohms (15VDC);
Internal protection: Fuse 6A T.
Physical Specifications:
Dimensions: 154mm X 110mm X 60mm DIN rail mounting (9
modules);
Self-extinguishing plastic box UL-94 V0;
Protection degree: IP20, for indoor use.
Compatibility:
Compatibility with iThink module: V1.0 or higher.
Compatibility with Mordomus software: Mordomus iThink
V2017 or higher.
ATTENTION:
Never open the housing.
Never remove the circuit board from its housing.
Never crimp or cut cables while they are connected
to powered equipment.
The module is not provided with additional protection
against short circuit, therefore it is recommended to
use a power supply with the correct specifications.
Mordomus shall not be liable for any damages
resulting from the use of our equipment outside the
specifications and/or for a purpose other than that
intended.
When using a low cross section cable there might be
voltage drops that could force the module into under-
voltage protection mode.
Only use power supplies with an output voltage of
iSND8
15V and at least 4A.
Do not connect loudspeakers with an impedance less
than 4 Ohms.
Overview:
MdiBus In connector
MdiBus Out connector
Power Supply iPSE154 (15V 4A)
Output connectors
Power supply connector 15VDC 2,5x5,5mm
Line Out from source A and B
Line Out from source C
Line In for sources A and B
Addressing button
Line inputs for sources 1 to 8
Line Input for source C
LED Status indicators
Connections:
Cross Section and specification of conductors:
MdiBus - CAT 6 UTP.
Outputs - Solid wire/ Stranded wire 1.5mm²
Connection table Outputs - refer to
image
1, nr.
Nr
Function
Nr
Function
1
Out Ch1 (+)
9
Out Ch5 (+)
2
Out Ch1 (-)
10
Out Ch5 (-)
3
Out Ch2 (+)
11
Out Ch6 (+)
4
Out Ch2 (-)
12
Out Ch6 (-)
5
Out Ch3 (+)
13
Out Ch7 (+)
6
Out Ch3 (-)
14
Out Ch7 (-)
7
Out Ch4 (+)
15
Out Ch8 (+)
8
Out Ch4 (-)
16
Out Ch8 (-)
HW 1.0
MDiBus connections: To connect the MDiBus, use CAT 6 UTP
cable with RJ45 connectors according to EIA568A or EIA568B
standards.
15VDC Power supply connection:
It is recommended to use the
iPSE154 power supply
provided with the iSND8 module. This
power supply should be connected directly to the DC IN connector
of the iSND8 module.
Input source connection: The line input IN A+B
iSND8 must be connected to the iThink module's audio output by
means of a stereo cable with a 3,5mm stereo audio jack on each
end. See
i mage 2
.
Every audio output of the iSND8 can select its audio source
from any of the audio inputs A, B
independently. In addition there is also one dedicated input for
each output that can also be selected
When more than one iSND8 are to be installed the iSND8
modules can be cascaded by using the line out Out A+B
of the first module as the source for the second module. This is
also applicable to channel C
.See
Enrollment:
To enroll the iSND8 module proceed as follows:
1.
Make sure that the iSND8 is powered by a suitable
power supply
and connected to the MdiBus
and
.
2.
In the Mordomus console access the menu
:
Configurations and acess the sub-menu
Modules/Addresses.
3.
On the iSND8, press and hold the addressing button
for at least 1sec. The green LED
slowly until the addressing is complete.
4.
The iSND8 should be added automatically to the list
and the green LED should stop blinking.
LED codes
:
Green LED ON: Module powered and enrolled to software;
Red LED ON: Module powered and not enrolled;
Green LED blinking shortly: Module receiving data;
Green LED blinking continuously: Module awaiting address;
Red LED blinking: Module sending/receiving data.
v.2045
15VDC Power supply interruption: After a power interruption of
the 15VDC supply, the iSND8 module will set all sound outputs to
Mute and the input selector will be set to input A.
Reset: To perform a reset to the module, interrupt the 15VDC
power supply for 5 seconds.
This product complies with the Electromagnetic
Compatibility Directive 2014/30/EU.
of the
This product conforms with the EU Directive 2011/65,
RoHS
regarding the restriction of use of certain hazardous
substances in electric and electronic devices.
For EU countries only.
All old electrical and electronic devices must be
separated from normal household waste and disposed
of at designated facilities. For further information
contact your local authorities, waste disposal office or
the shop where you bought the device.
http://mordomus.com/mordomus/docs/ithink/iSND8.pdf
or C
.
image
3.
will blink
PT