Functional Test; Using The Machine - HURAKAN HKN-PPF15 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
EN
Model
Voltage, V/Hz
A*B*C, mm
Capacity, kg
Performance, kg/h
Motor, HP
Power, W
Noise level, dB

3. FUNCTIONAL TEST

Before the functional test, make sure that the top cover and discharge door are safely locked,
then perform the functional test according to the following steps:
1) make sure that the top cover and discharge door are safely closed;
2) press the "START" button and then immediately press the "STOP" button;
3) repeat the same steps to make sure the cap rotates counterclockwise (Fig. 1) while observing
through the transparent closed top cover;
4) make sure that the machine stops during operation when the cover or discharge door is
opened, and if they are closed, the machine starts when the button"START" is pressed;
5) to unload the product, open the discharge door while holding it in the open
position with your right hand while simultaneously keeping the "OUT" and "START" buttons
pressed with your left hand; the machine will start unloading potatoes, which will pop out cen-
trifugally (Fig. 4).

4. USING THE MACHINE

4.1 Controls
1. "OUT"
(dynamic)
2. "STOP (Shutdown)"
3. "START"
4. "TIMER"
14
Dimensions and technical specifications
Figure 3 Cap rotation
HKN-PPF15
220/50
600*440*1075
15
165
1
750
≤75
Figure 2 Product loading

Publicidad

Tabla de contenido
loading

Tabla de contenido