Please read all instructions before installing
SPECIFICATIONS
Voltage ................................................................... 120VAC, 60Hz
Load (Single Pole Circuit)
Incandescent or fl uorescent ................................ 0-600 Watts
Fan motor ...................................................................... 1/6 hp
Time Delay Adjustment .............. 15 sec., 5 min., 15 min., 30 min.
Light Level Adjustment ........................................... 10 fc to 150 fc
Environment ...................................... Residential Indoor use only
Operating Temperature ....................32° to 131°F (0° to 55°C)
Humidity .......................................... 95% RH, non-condensing
Tools Needed
Insulated Screwdriver
Wire Strippers
DESCRIPTION AND OPERATION
RH-200 Multi-way Wall Switch Vacancy Sensors are designed to replace standard
multi-way (3-way, 4-way) switches. They are ideal for any room with multiple
entries such as living and dining rooms, family rooms, bedrooms, bathrooms,
hallways, and any other indoor space where vacancy sensor-based controls with
manual ON/OFF capability are desirable.
Like standard switches, you can press the ON/OFF button to turn the light or fan
(controlled load) ON and OFF. Unlike standard switches, the RH-200 automatically
turns OFF the controlled load after the coverage area has been vacant for a period
of time (Time Delay). If motion is detected within 30 seconds after it automatically
turns OFF, the RH-200 automatically turns the load back ON.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation,
it can be adjusted to work as an occupancy sensor that turns the controlled load
ON automatically upon detection of occupancy in the area.
Lighted Switch
To help you locate the RH-200 in a dark room, the amber LED illuminates the
ON/OFF button while the controlled load is OFF. When the controlled load is ON,
the LED is OFF.
Operating Modes
For multi-way operation the Operating Mode must be the same in all sensors
related to the same load. There are two operating modes to select from:
MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press
the ON/OFF button to turn the load ON. The RH-200 keeps the load ON until no
motion is detected by any of the related RH-200s for the time delay period. There
is also a 30 second reset delay after the automatic shut-off. If motion is detected
during this time, the sensor turns the load back on automatically. After the 30
second reset delay has elapsed, the ON/OFF button must be pressed to turn ON
the load.
MODE 2 Occupancy sensor (Auto-ON/OFF with manual control and reset to auto
after 5 minutes of vacancy): The load turns ON and OFF automatically based on
occupancy detection. Once turned ON the RH-200 keeps the load ON until no
motion is detected by any of the related RH-200s for the time delay period. If
the load is turned OFF manually, automatic-ON is re-enabled when no motion is
detected for 5 minutes. This prevents the load from being turned on after it was
deliberately turned OFF.
Call 888.817.0571 for Technical Support
RH-200
Multi-way
Wall Switch
Vacancy Sensor
with Manual ON/OFF
Lens
Lighted Switch
ON/OFF Button
Santa Clara, CA 95050

Publicidad

Tabla de contenido
loading

Resumen de contenidos para wattstopper RH-200

  • Página 1 MODE 1 Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press the ON/OFF button to turn the load ON. The RH-200 keeps the load ON until no motion is detected by any of the related RH-200s for the time delay period. There is also a 30 second reset delay after the automatic shut-off.
  • Página 2 Pull the old switch out from the wall box. 2. Identify the type of circuit. You may connect the RH-200 to a single pole or multi-way circuit. These instructions describe only the 3-way circuit application. For information about other applications, consult technical support or the Watt Stopper website.
  • Página 3 • Connect the power wire from the circuit box (HOT) to the black wire on the auxiliary RH-200 and to the TRAVELER 1 wire. • Connect the TRAVELER 1 wire from the black wire of the auxiliary RH-200 to the black wire of the master RH-200.
  • Página 4 ON automatically with occupancy if the light level measured at this sensor is above the current natural illumination. 5. Repeat the process (beginning with step 1) for each RH-200 in your multi-way confi guration until the Light Level has been adjusted properly in all of them.
  • Página 5: Test Mode

    4. Repeat as necessary to ensure that the desired coverage areas are within detection range. You can do this test for each RH-200 in your multi-way confi guration. So that you can determine the actual coverage area for each multi-way switch individually, only the RH-200 that is in TEST mode will control the load.
  • Página 6: Warranty Information

    Please Recycle 2800 De La Cruz Boulevard, Santa Clara, CA 95050 Technical Support: 888.817.0571 www.wattstopper.com/at home 06247r2 6/2007...
  • Página 7: Especificaciones

    área de cobertura. Interruptor Iluminado Para facilitar la ubicación del RH-200 en un cuarto oscuro, un LED color ámbar ilumina el botón de ENCENDIDO/APAGADO cuando la carga controlada se encuentra apagada. Cuando por el contrario esta última se encuentra encendida, el LED estará...
  • Página 8: Instalacion Y Cableado

    Para el mismo se pueden elegir los siguientes valores: 15 segundos, 5 minutos, 15 minutos y 30 minutos. Se recomienda que todos los RH-200 conectados en grupo sean confi gurados con el mismo tiempo de Retardo de Apagado. Para información adicional sobre cómo realizar lo anterior, por favor lea la sección de CONFIGURACION Y PROGRAMACION DEL SENSOR en este...
  • Página 9 únicamente para designar el sensor que esta conectado directamente a la carga controlada. • Conecte el cable de LINEA (o FASE) del circuito al cable negro del RH-200 auxiliar y al cable VIAJERO 1. • Conecte el cable VIAJERO 1 proveniente del cable negro del RH-200 auxiliar al cable negro del RH-200 maestro.
  • Página 10: Configuracion & Programacion Del Sensor

    ENCENDIDO/APAGADO. CONFIGURACION & PROGRAMACION DEL SENSOR Para confi gurar el sensor RH-200 usted debe utilizar los controles ubicados detrás del botón de ENCENDIDO/APAGADO. Es necesario desmontar la placa decorativa para obtener acceso al Botón de Selección...
  • Página 11: Modo De Prueba

    5. Repita este proceso (empezando con el paso 1) para cada RH-200 en su cableado tipo 3 o 4 vías hasta que el Nivel de Luz Natural haya sido ajustado apropiadamente en cada uno de los sensores.
  • Página 12: Solucion De Problemas

    • El tiempo del retardo de apagado puede ser confi gurado desde 15 segundos hasta 30 minutos. Corrobore el valor de Retardo de Apagado en cada RH-200. Asegúrese de que todos los RH-200 tienen el mismo valor.

Tabla de contenido